Mouse Arachidonate 5-lipoxygenase (Alox5) ELISA Kit (MOEB1201)
- SKU:
- MOEB1201
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P48999
- Range:
- 0.156-10 ng/mL
- ELISA Type:
- Sandwich
- Synonyms:
- 5-LO,, Arachidonate 5-Lipoxygenase
- Reactivity:
- Mouse
Description
Mouse Arachidonate 5-lipoxygenase (Alox5) ELISA Kit
The Mouse Arachidonate 5-Lipoxygenase (ALOX5) ELISA Kit is specially designed for the accurate measurement of ALOX5 levels in mouse serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity, ensuring precise and consistent results, making it ideal for various research purposes.ALOX5 is a key enzyme involved in the biosynthesis of leukotrienes, which play important roles in inflammation and immune responses. Dysregulation of ALOX5 has been implicated in various diseases, including asthma, atherosclerosis, and inflammatory disorders, highlighting its significance as a potential therapeutic target and biomarker for disease progression.
Overall, the Mouse ALOX5 ELISA Kit provides researchers with a valuable tool for studying the role of ALOX5 in health and disease, advancing our understanding of inflammatory processes and offering potential new avenues for treatment development.
Product Name: | Mouse Arachidonate 5-lipoxygenase (Alox5) ELISA Kit |
SKU: | MOEB1201 |
Size: | 96T |
Target: | Mouse Arachidonate 5-lipoxygenase (Alox5) |
Synonyms: | 5-LO |
Assay Type: | Sandwich |
Detection Method: | ELISA |
Reactivity: | Mouse |
Detection Range: | 0.156-10ng/mL |
Sensitivity: | 0.087ng/mL |
Intra CV: | 4.9% | ||||||||||||||||||||
Inter CV: | 6.8% | ||||||||||||||||||||
Linearity: |
| ||||||||||||||||||||
Recovery: |
| ||||||||||||||||||||
Function: | Catalyzes the first step in leukotriene biosynthesis, and thereby plays a role in inflammatory processes. |
Uniprot: | P48999 |
Sample Type: | Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids |
Specificity: | Natural and recombinant mouse Arachidonate 5-lipoxygenase |
Sub Unit: | Interacts with ALOX5AP and LTC4S. Interacts with COTL1, the interaction is required for stability and efficient catalytic activity. |
Research Area: | Cardiovascular |
Subcellular Location: | Cytoplasm Nucleus matrix Nucleus membrane Peripheral membrane protein Shuttles between cytoplasm and nucleus. Found exclusively in the nucleus, when phosphorylated on Ser-272. Calcium binding promotes translocation from the cytosol and the nuclear matrix to the nuclear envelope and membrane association (By similarity). |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | 5-LO: arachidonate 5-lipoxygenase. Arachidonic acid promotes its phosphorylation by p38 MAPK-regulated MAPKAP kinases. Upregulated in glioblastoma multiforme and colon, pancreatic and bladder cancer. |
UniProt Protein Details: | Protein type:Lipid Metabolism - arachidonic acid; Nuclear envelope; Oxidoreductase; Lipid Metabolism - linoleic acid; EC 1.13.11.34 Chromosomal Location of Human Ortholog: 10q11.2 Cellular Component: extracellular space; nuclear membrane; nuclear matrix; nuclear envelope lumen; nuclear envelope; cytosol Molecular Function:protein binding; iron ion binding; arachidonate 5-lipoxygenase activity Biological Process: leukotriene biosynthetic process; leukotriene production during acute inflammatory response; lipoxygenase pathway; arachidonic acid metabolic process; leukotriene metabolic process Disease: Asthma, Susceptibility To |
NCBI Summary: | This gene encodes a member of the lipoxygenase gene family and plays a dual role in the synthesis of leukotrienes from arachidonic acid. The encoded protein, which is expressed specifically in bone marrow-derived cells, catalyzes the conversion of arachidonic acid to 5(S)-hydroperoxy-6-trans-8,11,14-cis-eicosatetraenoic acid, and further to the allylic epoxide 5(S)-trans-7,9-trans-11,14-cis-eicosatetrenoic acid (leukotriene A4). Leukotrienes are important mediators of a number of inflammatory and allergic conditions. Mutations in the promoter region of this gene lead to a diminished response to antileukotriene drugs used in the treatment of asthma and may also be associated with atherosclerosis and several cancers. Alternatively spliced transcript variants encoding different isoforms have been found for this gene. [provided by RefSeq, Jan 2012] |
UniProt Code: | P48999 |
NCBI GenInfo Identifier: | 4502057 |
NCBI Gene ID: | 240 |
NCBI Accession: | NP_000689.1 |
UniProt Secondary Accession: | P48999,P48999, P12527, |
UniProt Related Accession: | P09917 |
Molecular Weight: | |
NCBI Full Name: | arachidonate 5-lipoxygenase isoform 1 |
NCBI Synonym Full Names: | arachidonate 5-lipoxygenase |
NCBI Official Symbol: | ALOX5 |
NCBI Official Synonym Symbols: | 5-LO; 5LPG; LOG5; 5-LOX |
NCBI Protein Information: | arachidonate 5-lipoxygenase |
UniProt Protein Name: | Arachidonate 5-lipoxygenase |
UniProt Gene Name: | ALOX5 |
UniProt Entry Name: | LOX5_HUMAN |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |