The Human Myosin X (MYO10) ELISA Kit is a reliable and accurate tool for the detection of MYO10 levels in human samples such as serum, plasma, and cell culture supernatants. This kit boasts high sensitivity and specificity, ensuring consistent and trustworthy results for a variety of research applications.MYO10 is a vital protein that plays a crucial role in cell motility and intracellular transport. Dysregulation of MYO10 has been linked to various diseases, including cancer, neurological disorders, and cardiovascular diseases.
By accurately quantifying MYO10 levels, researchers can gain valuable insights into disease mechanisms and potential therapeutic interventions.Overall, the Human Myosin X (MYO10) ELISA Kit is a valuable tool for researchers studying the role of MYO10 in health and disease, providing accurate and reliable data to advance understanding and potential treatments.
Product Name:
Human Myosin X (MYO10) ELISA Kit
Product Code:
HUDL01967
Size:
96 Assays
Target:
MYO10
Synonyms:
Unconventional Myosin-X, Unconventional Myosin-10
Detection Method:
Competition
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
90-103
96
Heparin plasma (n=5)
89-102
95
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. Note:To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 50µL standard or sample to each well.    And then add 50µL prepared Detection Reagent A immediately.    Shake and mix. Incubate 1 hour at 37°C
3.
Aspirate and wash 3 times
4.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
5.
Aspirate and wash 5 times
6.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
7.