Sheep Insulin Like Growth Factor 1 (IGF1) ELISA Kit
The Sheep Insulin-like Growth Factor 1 (IGF1) ELISA Kit is specifically designed for the detection of IGF1 levels in sheep serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit provides accurate and reproducible results, making it an essential tool for research in the fields of endocrinology and growth factor signaling.IGF1 is a key hormone that regulates growth and development in animals, including sheep. It plays a crucial role in skeletal growth, muscle development, and metabolism. By measuring IGF1 levels, researchers can gain valuable insights into various physiological and pathological processes, such as growth disorders, muscle wasting conditions, and metabolic diseases.
Whether studying the effects of nutrition, genetics, or environmental factors on sheep growth and development, the Sheep IGF1 ELISA Kit offers a reliable method for quantifying IGF1 levels in biological samples. This in turn can facilitate the discovery of novel therapeutic approaches and interventions for improving livestock health and performance.
Product Name:
Sheep Insulin Like Growth Factor 1 (IGF1) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.