Rat Sphingosine-1-phosphate lyase 1 (Sgpl1) ELISA Kit
The Rat Sphingosine-1-Phosphate Lyase 1 (SGPL1) ELISA Kit is specifically designed for the accurate detection of SGPL1 levels in rat serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity, ensuring reliable and reproducible results for a variety of research applications.SGPL1 is an important enzyme involved in the breakdown of sphingosine-1-phosphate, a bioactive lipid mediator that plays a crucial role in various cellular processes including cell growth, migration, and inflammation.
Dysregulation of SGPL1 has been implicated in diseases such as cancer, autoimmune disorders, and metabolic diseases, highlighting its potential as a biomarker for studying these conditions and developing therapeutic strategies.With its user-friendly format and superior performance, the Rat SGPL1 ELISA Kit is an indispensable tool for researchers investigating the role of SGPL1 in health and disease.
Product Name:
Rat Sphingosine-1-phosphate lyase 1 (Sgpl1) ELISA Kit
SKU:
RTEB1041
Size:
96T
Target:
Rat Sphingosine-1-phosphate lyase 1 (Sgpl1)
Synonyms:
Sphingosine-1-phosphate aldolase, S1PL, Spl
Assay Type:
Sandwich
Detection Method:
ELISA
Reactivity:
Rat
Detection Range:
78-5000pg/mL
Sensitivity:
26pg/mL
Intra CV:
4.3%
Inter CV:
7.1%
Linearity:
Sample
1:2
1:4
1:8
1:16
Serum(N=5)
111-111%
84-94%
98-108%
91-101%
EDTA Plasma(N=5)
95-104%
107-117%
103-115%
109-119%
Heparin Plasma(N=5)
97-109%
82-95%
103-113%
100-110%
Recovery:
Sample Type
Average(%)
Recovery Range(%)
Serum
91
85-97
Plasma
93
87-99
Function:
Cleaves phosphorylated sphingoid bases (PSBs), such as sphingosine-1-phosphate, into fatty aldehydes and phosphoethanolamine. Elevates stress-induced ceramide production and apoptosis.
Uniprot:
Q8CHN6
Sample Type:
Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Specificity:
Natural and recombinant rat Sphingosine-1-phosphate lyase 1
Sub Unit:
Homodimer.
Research Area:
Signal Transduction
Subcellular Location:
Endoplasmic reticulum membrane Single-pass type III membrane protein
Storage:
Please see kit components below for exact storage details
Note:
For research use only
UniProt Protein Function:
SGPL1: Cleaves phosphorylated sphingoid bases (PSBs), such as sphingosine-1-phosphate, into fatty aldehydes and phosphoethanolamine. Elevates stress-induced ceramide production and apoptosis. Belongs to the group II decarboxylase family. Sphingosine-1-phosphate lyase subfamily.Protein type: EC 4.1.2.27; Lipid Metabolism - sphingolipid; Lyase; Membrane protein, integral; ApoptosisCellular Component: endoplasmic reticulum; endoplasmic reticulum membrane; integral to membraneMolecular Function: carboxy-lyase activity; pyridoxal phosphate binding; sphinganine-1-phosphate aldolase activityBiological Process: androgen metabolic process; ceramide metabolic process; estrogen metabolic process; fatty acid metabolic process; female gonad development; hemopoiesis; kidney development; Leydig cell differentiation; luteinization; nitrogen compound metabolic process; palate development; platelet-derived growth factor receptor signaling pathway; post-embryonic development; regulation of multicellular organism growth; skeletal morphogenesis; spermatogenesis; sphingolipid catabolic process; vasculogenesis
UniProt Protein Details:
NCBI Summary:
catalyzes the conversion of phosphorylated long chain bases into ethanolamine phosphate and a fatty aldehyde in sphingolipid catabolism [RGD, Feb 2006]
Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
Incubator
Deionized or distilled water
Absorbent paper
Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step
1.
Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C.
2.
Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform.
3.
Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper.
4.
Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C.
5.
Repeat the wash process for five times as conducted in step 3.
6.
Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction.
7.
Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
8.
Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters.
9.
After experiment, store all reagents according to the specified storage temperature respectively until their expiry.
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type
Protocol
Serum
If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles.
Plasma
Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit.
Urine & Cerebrospinal Fluid
Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid.
Cell culture supernatant
Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately.
Cell lysates
Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Tissue homogenates
The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C.
Tissue lysates
Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Breast Milk
Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles.