The Rat Pepsinogen C (PGC) ELISA Kit is a powerful tool for researchers looking to accurately measure pepsinogen C levels in rat samples. This kit offers high sensitivity and specificity, allowing for precise and reliable results in serum, plasma, and cell culture supernatants.Pepsinogen C is an important enzyme involved in the digestion process, specifically in the activation of pepsin in the stomach.
Abnormal levels of pepsinogen C have been linked to various digestive disorders and diseases, making it a valuable biomarker for research and diagnostic purposes.With the Rat Pepsinogen C (PGC) ELISA Kit, researchers can confidently study the role of pepsinogen C in digestive health and disease, paving the way for potential therapeutic interventions and diagnostic advancements.
Product Name:
Rat Pepsinogen C (PGC) ELISA Kit
Product Code:
RTDL00826
Size:
96 Assays
Target:
PGC
Synonyms:
PG-C, Progastricsin, Gastricsin
Detection Method:
Sandwich
Range:
4.687-300ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.