Rat Macrophage MigRat ion Inhibitory Factor (MIF) ELISA Kit
The Rat Macrophage Migration Inhibitory Factor (MIF) ELISA Kit is a powerful tool for the precise and accurate measurement of MIF levels in rat samples. This kit offers exceptional sensitivity and specificity, allowing for reliable and consistent results in a variety of research settings.MIF is a key regulator of the immune response and inflammatory processes, playing a crucial role in various diseases such as autoimmune disorders, cancer, and inflammatory conditions. By detecting and quantifying MIF levels, researchers can gain valuable insights into the role of MIF in disease pathogenesis and progression, ultimately paving the way for the development of innovative therapeutic strategies.
With its user-friendly protocol and superior performance, the Rat MIF ELISA Kit is an indispensable resource for investigators looking to advance their understanding of MIF biology and its implications in disease. Trust Assay Genie for high-quality ELISA kits that deliver accurate and reproducible results to drive your research forward.
Product Name:
Rat Macrophage MigRat ion Inhibitory Factor (MIF) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.