The Rat Inhibin Beta E (INHBE) ELISA Kit is specifically designed for the precise quantification of Inhibin Beta E levels in rat serum, plasma, and cell culture supernatants. With exceptional sensitivity and specificity, this kit guarantees accurate and reproducible results, making it ideal for various research applications.Inhibin Beta E is a vital protein involved in the regulation of follicle-stimulating hormone (FSH) secretion and is essential for the control of reproductive function.
Its role in fertility, pregnancy, and hormonal regulation makes it a crucial biomarker for studying reproductive health and potential therapies.The Rat Inhibin Beta E ELISA Kit provides researchers with a reliable tool for measuring Inhibin Beta E levels in biological samples, offering valuable insights into reproductive processes and potential implications for fertility and hormonal disorders.
Product Name:
Rat Inhibin Beta E (INHbE) ELISA Kit
Product Code:
RTDL00578
Size:
96 Assays
Target:
INHbE
Synonyms:
INH-bE, Activin beta-E chain
Detection Method:
Sandwich
Range:
7.812-500 pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-99
91
EDTA plasma (n=5)
80-99
89
Heparin plasma (n=5)
82-99
90
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.