Rat High affinity immunoglobulin epsilon receptor subunit beta (Ms4a2) ELISA Kit
The Rat High-Affinity Immunoglobulin Epsilon Receptor Subunit Beta (MS4A2) ELISA Kit offered by AssayGenie is a reliable and efficient tool for the detection and quantification of MS4A2 levels in rat samples, including serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this ELISA kit ensures accurate and reproducible results, making it suitable for a variety of research applications.MS4A2, also known as FcεRI-beta, is a critical component of the high-affinity IgE receptor involved in allergic reactions and immune responses.
It plays a crucial role in mediating mast cell activation and degranulation, leading to the release of inflammatory mediators. By studying MS4A2 levels, researchers can gain valuable insights into the mechanisms underlying allergic diseases and potentially identify new therapeutic targets.Overall, the Rat High-Affinity Immunoglobulin Epsilon Receptor Subunit Beta (MS4A2) ELISA Kit from AssayGenie is a valuable tool for researchers looking to explore the role of MS4A2 in immune responses and allergic disorders.
Product Name:
Rat High affinity immunoglobulin epsilon receptor subunit beta (Ms4a2) ELISA Kit
SKU:
RTEB1257
Size:
96T
Target:
Rat High affinity immunoglobulin epsilon receptor subunit beta (Ms4a2)
Synonyms:
Fc epsilon receptor I beta-chain, IgE Fc receptor subunit beta, Membrane-spanning 4-domains subfamily A member 2, FcERI, Fce1b, Fcer1b
Assay Type:
Sandwich
Detection Method:
ELISA
Reactivity:
Rat
Detection Range:
78-5000pg/ml
Sensitivity:
41.5pg/mL
Intra CV:
5.9%
Inter CV:
8.2%
Linearity:
Sample
1:2
1:4
1:8
1:16
Serum(N=5)
96-105%
106-114%
103-112%
107-119%
EDTA Plasma(N=5)
98-107%
90-99%
104-117%
101-110%
Heparin Plasma(N=5)
82-92%
98-108%
98-106%
94-107%
Recovery:
Sample Type
Average(%)
Recovery Range(%)
Serum
86
80-92
Plasma
88
82-94
Function:
High affinity receptor that binds to the Fc region of immunoglobulins epsilon. Aggregation of FCER1 by multivalent antigens is required for the full mast cell response, including the release of preformed mediators (such as histamine) by degranulation and de novo production of lipid mediators and cytokines. Also mediates the secretion of important lymphokines. Binding of allergen to receptor-bound IgE leads to cell activation and the release of mediators responsible for the manifestations of allergy.
Uniprot:
P13386
Sample Type:
Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Specificity:
Natural and recombinant rat High affinity immunoglobulin epsilon receptor subunit beta
Sub Unit:
Tetramer of an alpha chain, a beta chain, and two disulfide linked gamma chains. Binds LILRB1. Interacts with FES/FPS and LYN (By similarity). Interacts with FGR.
Subcellular Location:
Membrane Multi-pass membrane protein
Storage:
Please see kit components below for exact storage details
Note:
For research use only
UniProt Protein Function:
FcER1B: High affinity receptor that binds to the Fc region of immunoglobulins epsilon. Aggregation of FCER1 by multivalent antigens is required for the full mast cell response, including the release of preformed mediators (such as histamine) by degranulation and de novo production of lipid mediators and cytokines. Also mediates the secretion of important lymphokines. Binding of allergen to receptor-bound IgE leads to cell activation and the release of mediators responsible for the manifestations of allergy. Belongs to the MS4A family.Protein type: Receptor, misc.; Membrane protein, multi-pass; Membrane protein, integralCellular Component: endosome; external side of plasma membrane; Fc-epsilon receptor I complex; integral to plasma membrane; lipid raftMolecular Function: IgE binding; IgE receptor activity; phosphoprotein binding; protein kinase binding; SH2 domain bindingBiological Process: cell surface receptor linked signal transduction; cytokine secretion; immune response; inflammatory response; phospholipase C activation; positive regulation of mast cell degranulation; protein kinase C activation; regulation of release of sequestered calcium ion into cytosol; signal transduction
UniProt Protein Details:
NCBI Summary:
beta chain of the high affinity receptor for immunoglobulin E [RGD, Feb 2006]
high affinity immunoglobulin epsilon receptor subunit beta
NCBI Synonym Full Names:
membrane spanning 4-domains A2
NCBI Official Symbol:
Ms4a2
NCBI Official Synonym Symbols:
FCIGA; Ms4a1; Fcer1b
NCBI Protein Information:
high affinity immunoglobulin epsilon receptor subunit beta
UniProt Protein Name:
High affinity immunoglobulin epsilon receptor subunit beta
UniProt Synonym Protein Names:
Fc epsilon receptor I beta-chain; IgE Fc receptor subunit beta; Membrane-spanning 4-domains subfamily A member 2
Protein Family:
High affinity immunoglobulin epsilon receptor
UniProt Gene Name:
Ms4a2
UniProt Entry Name:
FCERB_RAT
Component
Quantity (96 Assays)
Storage
ELISA Microplate (Dismountable)
8×12 strips
-20°C
Lyophilized Standard
2
-20°C
Sample Diluent
20ml
-20°C
Assay Diluent A
10mL
-20°C
Assay Diluent B
10mL
-20°C
Detection Reagent A
120µL
-20°C
Detection Reagent B
120µL
-20°C
Wash Buffer
30mL
4°C
Substrate
10mL
4°C
Stop Solution
10mL
4°C
Plate Sealer
5
-
Other materials and equipment required:
Microplate reader with 450 nm wavelength filter
Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
Incubator
Deionized or distilled water
Absorbent paper
Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step
1.
Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C.
2.
Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform.
3.
Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper.
4.
Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C.
5.
Repeat the wash process for five times as conducted in step 3.
6.
Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction.
7.
Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
8.
Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters.
9.
After experiment, store all reagents according to the specified storage temperature respectively until their expiry.
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type
Protocol
Serum
If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles.
Plasma
Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit.
Urine & Cerebrospinal Fluid
Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid.
Cell culture supernatant
Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately.
Cell lysates
Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Tissue homogenates
The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C.
Tissue lysates
Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Breast Milk
Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles.