The Rat Ficolin-1 (FCN1) ELISA Kit is specifically designed for the accurate and sensitive detection of Ficolin-1 levels in rat serum, plasma, and tissue homogenates. This kit provides researchers with a reliable tool for studying the role of Ficolin-1 in the innate immune response and its involvement in various disease states.Ficolin-1 is a key player in the innate immune system, acting as a pattern recognition molecule that binds to specific targets and initiates the complement cascade. Its dysregulation has been linked to inflammatory diseases, autoimmune disorders, and infections, highlighting its importance as a potential biomarker for disease diagnosis and therapeutic interventions.
With high sensitivity and specificity, the Rat Ficolin-1 (FCN1) ELISA Kit offers precise and reproducible results, making it an invaluable tool for researchers in the field of immunology and biomarker discovery. Order now to advance your research and uncover the therapeutic potential of targeting Ficolin-1 in various pathological conditions.
Product Name:
Rat Ficolin 1 (FCN1) ELISA Kit
Product Code:
RTDL00365
Size:
96 Assays
Target:
FCN1
Synonyms:
FCNM, Collagen/fibrinogen domain-containing protein 1, Ficolin-alpha, Ficolin-A, M-ficolin
Detection Method:
Sandwich
Range:
0.781-50ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.