Rabbit Transforming Growth Factor Beta Induced Protein (TGFbI) ELISA Kit
The Rabbit Transforming Growth Factor Beta-Induced Protein (TGFBI) ELISA Kit is specially designed for the precise measurement of TGFBI levels in rabbit samples such as serum, plasma, and tissue homogenates. This kit offers superior sensitivity and specificity, ensuring accurate and consistent results for various research purposes.TGFBI is a critical protein that is induced by transforming growth factor beta and plays a key role in various cellular processes such as cell adhesion, migration, and proliferation.
Dysregulation of TGFBI has been linked to a variety of diseases including cancer, corneal dystrophies, and neurodegenerative disorders, making it a valuable biomarker for disease research and potential therapeutic interventions.With its user-friendly protocol and reliable performance, the Rabbit TGFBI ELISA Kit is the perfect tool for researchers exploring the role of TGFBI in physiological and pathological processes. Trust in this kit to deliver precise and reproducible results for your experiments.
Product Name:
Rabbit Transforming Growth Factor Beta Induced Protein (TGFbI) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-99
91
EDTA plasma (n=5)
80-99
89
Heparin plasma (n=5)
82-99
90
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.