The Rabbit Angiotensin II (AngII) ELISA Kit is specifically designed for the quantitative detection of Angiotensin II levels in rabbit serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and accuracy, ensuring precise and reliable results for a variety of research purposes.Angiotensin II is a key component in the renin-angiotensin system, regulating blood pressure, fluid balance, and electrolyte levels. Dysregulation of Angiotensin II levels has been linked to various cardiovascular diseases, kidney disorders, and hypertension, making it an important biomarker for studying these conditions and developing potential treatments.
With its high-quality components and user-friendly protocol, the Rabbit Angiotensin II (AngII) ELISA Kit is a valuable tool for researchers working in the fields of cardiology, nephrology, and hypertension studies. Get accurate and consistent Angiotensin II measurements with this reliable ELISA kit.
Product Name:
Rabbit Angiotensin II (AngII) ELISA Kit
Product Code:
RBDL00004
Size:
96 Assays
Target:
AngII
Synonyms:
Ang-II, Angiotensin-2
Detection Method:
Competition
Range:
31.25-2000pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. Note:To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 50µL standard or sample to each well.    And then add 50µL prepared Detection Reagent A immediately.    Shake and mix. Incubate 1 hour at 37°C
3.
Aspirate and wash 3 times
4.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
5.
Aspirate and wash 5 times
6.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
7.
Add 50µL Stop Solution. Read at 450 nm immediately.