The Porcine Vascular Endothelial Growth Factor Receptor 2 (VEGFR2) ELISA Kit is a powerful tool for the quantitative measurement of VEGFR2 levels in porcine samples. VEGFR2 is a key receptor involved in the regulation of angiogenesis and plays a crucial role in various physiological and pathological processes.This kit offers high sensitivity and specificity, ensuring accurate and reliable results for various research applications. It is suitable for measuring VEGFR2 levels in serum, plasma, and cell culture supernatants, providing valuable insights into the role of VEGFR2 in different biological processes.
Whether studying vascular development, cancer progression, or other angiogenesis-related conditions, the Porcine VEGFR2 ELISA Kit is an essential tool for researchers looking to gain a deeper understanding of VEGFR2 biology and its potential therapeutic applications.
CD309, FLK1, VEGFR, KDR, A Type III Receptor Tyrosine Kinase, Kinase Insert Domain Receptor, Kinase Insert Domain Receptor, Fetal Liver Kinase-1
Detection Method:
Sandwich
Range:
1.56-100ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.