Mouse Very Low Density Lipoprotein Receptor (VLDLR) ELISA Kit
- SKU:
- MODL01387
- Product Type:
- ELISA Kit
- Sensitivity:
- 0.53ng/mL
- Range:
- 1.56-100ng/mL
- ELISA Type:
- Sandwich
- Synonyms:
- VLDL-R
- Reactivity:
- Mouse
- Sample Type:
- Tissue Homogenates And Other Biological Fluids
Description
Mouse Very Low Density Lipoprotein Receptor (VLDLR) ELISA Kit
The Mouse Very Low Density Lipoprotein Receptor (VLDLR) ELISA Kit is specifically designed for the accurate detection and quantification of VLDLR levels in mouse serum, plasma, and cell culture supernatants. This kit is highly sensitive and specific, ensuring reliable and reproducible results for a wide range of research applications.VLDLR is an essential protein involved in lipid metabolism and cardiovascular health. Dysfunction of VLDLR has been linked to various diseases such as atherosclerosis, obesity, and metabolic disorders.
Therefore, measuring VLDLR levels can provide important insights into these conditions and aid in the development of potential therapeutic interventions.The Mouse VLDLR ELISA Kit is a valuable tool for researchers studying lipid metabolism, cardiovascular diseases, and metabolic disorders. With its high-quality performance and accuracy, this kit is a crucial asset for advancing scientific understanding and developing novel treatment strategies.
Product Name: | Mouse Very Low Density Lipoprotein Receptor (VLDLR) ELISA Kit |
Product Code: | MODL01387 |
Size: | 96 Assays |
Target: | VLDLR |
Synonyms: | VLDL-R |
Detection Method: | Sandwich |
Range: | 1.56-100ng/mL |
Shelf Life: | 12 months |
Note: | For research use only |
Recovery: | Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples. | ||||||||||||||||||||
| |||||||||||||||||||||
Linearity: | The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. | ||||||||||||||||||||
| |||||||||||||||||||||
Intra-assay Precision: | Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively. | ||||||||||||||||||||
Inter-assay Precision: | Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate. | ||||||||||||||||||||
Stability: | The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end. |
Step | Protocol |
1. | Prepare all reagents, samples and standards |
2. | Add 100µL standard or sample to each well. Incubate 2 hours at 37°C |
3. | Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C |
4. | Aspirate and wash 3 times |
5. | Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C |
6. | Aspirate and wash 5 times |
7. | Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C |
8. | Add 50µL Stop Solution. Read at 450nm immediately. |