Mouse Ubiquinol Cytochrome C Reductase Core Protein II (UQCRC2) ELISA Kit
The Mouse Ubiquinol-Cytochrome C Reductase Core Protein II (UQCRC2) ELISA Kit is a highly accurate and reliable tool for the detection of UQCRC2 levels in mouse serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit is suitable for a variety of research applications.UQCRC2 is a core protein in the ubiquinol-cytochrome c reductase complex, playing a crucial role in the electron transport chain and energy production. Dysregulation of UQCRC2 has been implicated in various diseases, including metabolic disorders and mitochondrial dysfunction.
Therefore, quantifying UQCRC2 levels can provide valuable insights into disease mechanisms and potential therapeutic targets.Overall, the Mouse UQCRC2 ELISA Kit is a valuable tool for researchers studying mitochondrial function, energy metabolism, and related diseases in mouse models. Its accuracy and reproducibility make it a trusted choice for high-quality research.
Product Name:
Mouse Ubiquinol Cytochrome C Reductase Core Protein II (UQCRC2) ELISA Kit
Product Code:
MODL01363
Size:
96 Assays
Target:
UQCRC2
Synonyms:
QCR2, UQCR2, Cytochrome b-c1 complex subunit 2, mitochondrial, Complex III subunit 2, Core protein II
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.