Mouse Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) ELISA Kit
The Mouse Tissue Inhibitors of Metalloproteinase 3 (TIMP3) ELISA Kit is a highly sensitive and specific assay designed for the accurate measurement of TIMP3 levels in mouse tissue samples. This kit provides researchers with reliable and reproducible results, making it an essential tool for studying the role of TIMP3 in various physiological processes.TIMP3 is a crucial regulator of matrix metalloproteinases, enzymes that play a key role in various biological processes such as tissue remodeling, inflammation, and angiogenesis.
Dysregulation of TIMP3 has been implicated in a wide range of diseases including cancer, cardiovascular diseases, and neurodegenerative disorders, highlighting its importance as a potential therapeutic target.With its high sensitivity and specificity, the Mouse TIMP3 ELISA Kit is an invaluable tool for researchers looking to investigate the role of TIMP3 in health and disease, and for developing novel therapeutic strategies targeting this protein.
Product Name:
Mouse Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.