Mouse Monokine Induced By Interferon Gamma (MIg) ELISA Kit
The Mouse Monokine Induced by Interferon Gamma (MIG) ELISA Kit is specifically designed for the quantitative measurement of MIG levels in mouse serum, plasma, and tissue homogenates. This kit offers unparalleled sensitivity and specificity, ensuring accurate and reproducible results for a variety of research applications.MIG, also known as CXCL9, is a chemokine that plays a critical role in the immune response by attracting T cells to sites of inflammation. It is involved in various immune-related processes, including T cell activation, migration, and effector function.
Measuring MIG levels can provide valuable insights into immune system regulation and the pathogenesis of inflammatory diseases.By using the Mouse MIG ELISA Kit, researchers can better understand the role of MIG in various disease states, such as autoimmune disorders, infectious diseases, and cancer. This kit is an essential tool for studying the immune response and developing potential therapeutic interventions targeting MIG signaling pathways.
Product Name:
Mouse Monokine Induced By Interferon Gamma (MIg) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.