The Mouse Monoamine Oxidase A (MAOA) ELISA Kit is a powerful tool for measuring levels of MAOA in mouse serum, plasma, and tissue lysate samples. This kit offers high sensitivity and specificity, providing accurate and reliable results for a variety of research applications.MAOA is an important enzyme involved in the breakdown of neurotransmitters such as serotonin, norepinephrine, and dopamine. Dysregulation of MAOA activity has been linked to various neurological and psychiatric disorders, making it a valuable biomarker for studying these conditions and exploring potential treatment strategies.
With its easy-to-use protocol and robust performance, the Mouse MAOA ELISA Kit is a valuable asset for researchers investigating the role of MAOA in mouse models of disease and drug development studies. Trust Assay Genie for all your ELISA kit needs.
Product Name:
Mouse Monoamine Oxidase A (MAOA) ELISA Kit
Product Code:
MODL00836
Size:
96 Assays
Target:
MAOA
Synonyms:
MAO-A, Amine oxidase [flavin-containing] A
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.