Mouse Lysyl Oxidase Like Protein 1 (LOXL1) ELISA Kit
The Mouse LOXL1 (Lysyl Oxidase-Like Protein 1) ELISA Kit is designed for the accurate detection of LOXL1 levels in mouse serum, plasma, and cell culture supernatants. This kit features high sensitivity and specificity, ensuring reliable and reproducible results for your research needs.LOXL1 is an important protein involved in extracellular matrix remodeling and plays a role in the development of conditions such as glaucoma and pseudoexfoliation syndrome.
By measuring LOXL1 levels, researchers can gain valuable insights into the mechanisms underlying these conditions and potentially develop new therapeutic strategies.Overall, the Mouse LOXL1 ELISA Kit is a valuable tool for studying LOXL1 biology and its implications in disease pathogenesis, providing researchers with a reliable platform for their experiments.
Product Name:
Mouse Lysyl Oxidase Like Protein 1 (LOXL1) ELISA Kit
Product Code:
MODL00813
Size:
96 Assays
Target:
LOXL1
Synonyms:
LOL, LOXL, Lysyl oxidase homolog 1
Detection Method:
Sandwich
Range:
31.25-2,000pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.