The Mouse Lipase Lipoprotein LipD ELISA Kit is specifically developed for the precise measurement of lipase lipoprotein lipD levels in mouse serum, plasma, and cell culture supernatants. This kit is highly sensitive and specific, ensuring accurate and consistent results for various research purposes.Lipase lipoprotein lipD is an important enzyme involved in lipid metabolism and plays a key role in the breakdown of lipoproteins. It is crucial for maintaining proper lipid levels in the body and is associated with conditions such as dyslipidemia, obesity, and cardiovascular diseases.
Studying lipase lipoprotein lipD levels can provide valuable insights into these conditions and aid in the development of potential therapeutic interventions.Overall, the Mouse Lipase Lipoprotein LipD ELISA Kit is an essential tool for researchers studying lipid metabolism and related disorders in mouse models, offering reliable and reproducible results for a wide range of research applications.
Product Name:
Mouse Lipase, Lipoprotein (LIPD) ELISA Kit
Product Code:
MODL00806
Size:
96 Assays
Target:
LIPD
Synonyms:
LPL, Lipoprotein Lipase
Detection Method:
Sandwich
Range:
78.125-5,000pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.