The Mouse Kelch-like Protein 17 (KLHL17) ELISA Kit from Assay Genie is designed for the accurate and reliable detection of KLHL17 levels in mouse serum, plasma, and cell culture supernatants. This kit features high sensitivity and specificity, ensuring precise and reproducible results for a variety of research applications.KLHL17 is a key protein involved in cellular processes such as protein degradation, cell signaling, and cytoskeleton organization.
Dysregulation of KLHL17 has been linked to various diseases, including cancer, neurological disorders, and autoimmune conditions, making it a valuable biomarker for studying these conditions and developing potential treatments.Trust Assay Genie's Mouse KLHL17 ELISA Kit for robust and consistent results in your research on KLHL17 and its role in disease pathology. Order now and take your research to the next level.
Product Name:
Mouse Kelch-like protein 17 (Klhl17) ELISA Kit
SKU:
MOEB1526
Size:
96T
Target:
Mouse Kelch-like protein 17 (Klhl17)
Synonyms:
Actinfilin
Assay Type:
Sandwich
Detection Method:
ELISA
Reactivity:
Mouse
Detection Range:
62.5-4000pg/mL
Sensitivity:
31.42pg/mL
Intra CV:
Provided with the Kit
Inter CV:
Provided with the Kit
Linearity:
Provided with the Kit
Recovery:
Provided with the Kit
Function:
Substrate-recognition component of some cullin-RING-based BCR (BTB-CUL3-RBX1) E3 ubiquitin-protein ligase complex. The BCR(KLHL17) mediates the ubiquitination and subsequenct degradation of GLUR6. May play a role in the actin-based neuronal function.
Uniprot:
Q6TDP3
Sample Type:
Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Specificity:
Natural and recombinant mouse Kelch-like protein 17
Sub Unit:
Interacts with F-actin; the interaction disruptes the F-actin structures and leads to marked changes of neuronal morphology. Component of a complex, composed of PDZK1, SYNGAP1, KLHL17 and NMDA receptors. Interacts directly with PDZK1 (via PDZ1 domain); the interaction is important for integrity of actin cytoskeleton structures in neurons. Interacts with DLG4 and SYNGAP1. Interacts (via kelch repeats) with GRIK2 (via C-terminus); the interaction targets GRIK2 for degradation via ubiquitin-proteasome pathway. Interacts with GRIK1. Interacts with (via BTB domain) CUL3; the interaction regulates surface GRIK2 expression.
Please see kit components below for exact storage details
Note:
For research use only
UniProt Protein Function:
Actinfilin: Substrate-recognition component of some cullin-RING- based BCR (BTB-CUL3-RBX1) E3 ubiquitin-protein ligase complex. The BCR(KLHL17) mediates the ubiquitination and subsequenct degradation of GLUR6. May play a role in the actin-based neuronal function.Protein type: Ubiquitin conjugating system; Actin-bindingCellular Component: dendrite cytoplasm; postsynaptic membrane; extracellular space; cell soma; membrane; postsynaptic density; plasma membrane; synapse; cell junction; actin cytoskeletonMolecular Function: actin filament binding; protein complex scaffold; actin binding; POZ domain bindingBiological Process: actin cytoskeleton organization and biogenesis
Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
Incubator
Deionized or distilled water
Absorbent paper
Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step
1.
Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C.
2.
Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform.
3.
Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper.
4.
Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C.
5.
Repeat the wash process for five times as conducted in step 3.
6.
Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction.
7.
Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
8.
Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters.
9.
After experiment, store all reagents according to the specified storage temperature respectively until their expiry.
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type
Protocol
Serum
If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles.
Plasma
Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit.
Urine & Cerebrospinal Fluid
Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid.
Cell culture supernatant
Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately.
Cell lysates
Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Tissue homogenates
The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C.
Tissue lysates
Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Breast Milk
Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles.