Mouse Calcineurin subunit B type 1 (Ppp3r1) ELISA Kit
The Mouse Calcineurin Subunit B Type 1 (PPP3R1) ELISA Kit is a valuable tool for the quantitative measurement of PPP3R1 levels in mouse serum, plasma, and cell lysates. This kit offers exceptional sensitivity and specificity, ensuring accurate and reproducible results for various research applications.PPP3R1 is a key regulatory subunit of calcineurin, a calcium-dependent phosphatase involved in diverse cellular processes such as immune response, cardiac hypertrophy, and neuronal signaling. Dysregulation of calcineurin signaling has been implicated in various diseases, including autoimmune disorders, cardiac dysfunction, and neuroinflammatory conditions, highlighting the importance of studying PPP3R1 levels as a potential biomarker for these conditions.
Overall, the Mouse Calcineurin Subunit B Type 1 (PPP3R1) ELISA Kit is a valuable tool for researchers working in the fields of immunology, cardiovascular biology, and neuroscience, providing reliable data for understanding the role of PPP3R1 in health and disease.
Product Name:
Mouse Calcineurin subunit B type 1 (Ppp3r1) ELISA Kit
SKU:
MOEB1159
Size:
96T
Target:
Mouse Calcineurin subunit B type 1 (Ppp3r1)
Synonyms:
Protein phosphatase 2B regulatory subunit 1, Protein phosphatase 3 regulatory subunit B alpha isoform 1, Cnb
Assay Type:
Sandwich
Detection Method:
ELISA
Reactivity:
Mouse
Detection Range:
0.156-10ng/mL
Sensitivity:
0.085ng/mL
Intra CV:
Provided with the Kit
Inter CV:
Provided with the Kit
Linearity:
Provided with the Kit
Recovery:
Provided with the Kit
Function:
Regulatory subunit of calcineurin, a calcium-dependent, calmodulin stimulated protein phosphatase. Confers calcium sensitivity.
Uniprot:
Q63810
Sample Type:
Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids
Specificity:
Natural and recombinant mouse Calcineurin subunit B type 1
Sub Unit:
Composed of a catalytic subunit (A) and a regulatory subunit (B). Isoform 1 and isoform 2 interact with CIB1 (via C-terminal region); the interaction increases upon cardiomyocytes hypertrophy.
Research Area:
Neurosciences
Subcellular Location:
Cytoplasm Cytosol Cell membrane Cell membrane Sarcolemma Cell membrane Lipid-anchor Translocates from the cytosol to the sarcolemma in a CIB1-dependent manner during cardiomyocytes hypertrophy.
Storage:
Please see kit components below for exact storage details
Note:
For research use only
UniProt Protein Function:
PPP3R1: Regulatory subunit of calcineurin, a calcium-dependent, calmodulin stimulated protein phosphatase. Confers calcium sensitivity. Belongs to the calcineurin regulatory subunit family.Protein type: Apoptosis; Protein phosphatase, regulatory subunit; Cell development/differentiation; Motility/polarity/chemotaxisCellular Component: calcineurin complex; cytoplasm; membrane; plasma membrane; sarcolemmaMolecular Function: calcium ion binding; enzyme binding; metal ion binding; phosphoprotein phosphatase activity; protein binding; protein domain specific bindingBiological Process: calcineurin-NFAT signaling pathway; epithelial to mesenchymal transition; heart development; myelination in the peripheral nervous system; NFAT protein import into nucleus; patterning of blood vessels; positive regulation of NFAT protein import into nucleus; positive regulation of transcription from RNA polymerase II promoter; protein amino acid dephosphorylation; Schwann cell development
protein phosphatase 3, regulatory subunit B, alpha isoform (calcineurin B, type I)
NCBI Official Symbol:
Ppp3r1
NCBI Official Synonym Symbols:
Cnb1; CaNB1; MCIP1
NCBI Protein Information:
calcineurin subunit B type 1
UniProt Protein Name:
Calcineurin subunit B type 1
UniProt Synonym Protein Names:
Protein phosphatase 2B regulatory subunit 1; Protein phosphatase 3 regulatory subunit B alpha isoform 1
Protein Family:
Calcineurin
UniProt Gene Name:
Ppp3r1
UniProt Entry Name:
CANB1_MOUSE
Component
Quantity (96 Assays)
Storage
ELISA Microplate (Dismountable)
8×12 strips
-20°C
Lyophilized Standard
2
-20°C
Sample Diluent
20ml
-20°C
Assay Diluent A
10mL
-20°C
Assay Diluent B
10mL
-20°C
Detection Reagent A
120µL
-20°C
Detection Reagent B
120µL
-20°C
Wash Buffer
30mL
4°C
Substrate
10mL
4°C
Stop Solution
10mL
4°C
Plate Sealer
5
-
Other materials and equipment required:
Microplate reader with 450 nm wavelength filter
Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
Incubator
Deionized or distilled water
Absorbent paper
Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step
1.
Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C.
2.
Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform.
3.
Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper.
4.
Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C.
5.
Repeat the wash process for five times as conducted in step 3.
6.
Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction.
7.
Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
8.
Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters.
9.
After experiment, store all reagents according to the specified storage temperature respectively until their expiry.
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type
Protocol
Serum
If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles.
Plasma
Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit.
Urine & Cerebrospinal Fluid
Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid.
Cell culture supernatant
Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately.
Cell lysates
Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Tissue homogenates
The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C.
Tissue lysates
Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C.
Breast Milk
Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles.