The Mouse Adiponectin Receptor 1 (ADIPOR1) ELISA Kit is a highly sensitive and specific assay designed for the precise measurement of ADIPOR1 levels in mouse serum, plasma, and cell culture supernatants. This kit offers reliable and reproducible results, making it perfect for a variety of research applications.ADIPOR1 is a key receptor involved in mediating the effects of adiponectin, a hormone that plays a critical role in regulating metabolism and insulin sensitivity.
Dysregulation of adiponectin signaling is associated with various metabolic disorders such as obesity, type 2 diabetes, and cardiovascular diseases. The Mouse ADIPOR1 ELISA Kit provides a valuable tool for studying the role of ADIPOR1 in these conditions and exploring potential therapeutic strategies.
Product Name:
Mouse Adiponectin Receptor 1 (ADIPOR1) ELISA Kit
Product Code:
MODL00027
Size:
96 Assays
Target:
ADIPOR1
Synonyms:
ACDCR1, CGI45, PAQR1, TESBP1A, TESBP1-A, Progestin and AdipoQ Receptor Family Member I
Detection Method:
Sandwich
Range:
3.125-200ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-101
91
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.