The Human Vitamin D Binding Protein (DBP) ELISA Kit is a highly reliable and sensitive assay designed for the accurate detection of vitamin D binding protein levels in human serum, plasma, and cell culture supernatants. This ELISA kit offers high specificity and precision, ensuring consistent and reproducible results for a wide range of research applications.Vitamin D binding protein is a key protein involved in the transport and metabolism of vitamin D in the body. It plays a crucial role in regulating vitamin D levels and is associated with various health conditions such as bone health, immune function, and chronic diseases.
As a key biomarker, studying vitamin D binding protein levels can provide valuable insights into vitamin D status and its impact on overall health.Whether you are conducting research in the fields of bone health, endocrinology, immunology, or chronic diseases, the Human Vitamin D Binding Protein (DBP) ELISA Kit is an essential tool for measuring and analyzing vitamin D binding protein levels accurately and efficiently. Trust Assay Genie for high-quality ELISA kits that deliver reliable results for your research needs.
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.