Human VCAM-1 PharmaGenie ELISA Kit (SBRS1222)
- SKU:
- SBRS1222
- Product Type:
- ELISA Kit
- Reactivity:
- Human
- Applications:
- ELISA
- ELISA Type:
- Sandwich
Frequently bought together:
Description
system_update_altDatasheet
Human VCAM-1 PharmaGenie ELISA Kit (SBRS1222)
Product SKU: | SBRS1222 |
Size: | 96T |
Application: | This ELISA kit shows no cross-reactivity with any of the cytokines tested: Human Angiopoietin-1, Angiostatin , B7-1, BMP-7, CD14, CD30, CD40, CD40 Ligand, CTLA-4, CXCL16, Dkk-4, DR6, Endostatin, E-Selectin, Follistatin, HB-EGF, HVEM, ICAM-2, IGF-II, IL-10 Ra, IL-10 Rb, IL-18, IL-9 , IL-2 Ra, IL-2 Rb, IL-5 Ra, LAP, L-Selectin, MCSF R, MMP-1, 2, 3, 7, 8, 9, 10,12 and 13, PDGF-AB, SDF-1b, Tie-1, Tie- 2, TIMP-3. |
Uniprot: | P19320 |
Gene ID: | 7412 |
Gene Names: | L1CAM / VCAM1 |
Synonyms: | Vascular cell adhesion protein 1 (V-CAM 1) (VCAM-1) (INCAM-100) (CD antigen CD106) |
Target Species: | Human |
Compatible Sample Types: | Cell Culture Supernatants, Plasma, Serum |
Design Principle: | Sandwich-based |
Method of Detection: | Colorimetric |
Quantitative/Semi-Quantitative: | Quantitative |
Range: | 0.3 ng/ml - 60 ng/ml |
Sensitivity: | 300 pg/ml |
Recommended Dilution: | 10 - 50 fold |
Storage/Stability: | The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C. |
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
Other materials and equipment required:
The Assay Genie Human VCAM-1 PharmaGenie ELISA Kit (SBRS1222) will require other equipment and materials to carry out the assay. Please see list below for further details.
- Distilled or deionized water
- Precision pipettes to deliver 2 ul to 1 ul volumes
- Adjustable 1-25 ul pipettes for reagent preparation
- 100 ul and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
- Prepare all reagents, samples and standards as instructed in the manual.
- Add 100 ul of standard or sample to each well.
- Incubate 2.5 h at RT or O/N at 4°C.
- Add 100 ul of prepared biotin antibody to each well.
- Incubate 1 h at RT.
- Add 100 ul of prepared Streptavidin solution to each well.
- Incubate 45 min at RT.
- Add 100 ul of TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 ul of Stop Solution to each well.
- Read at 450 nm immediately.