Human Tumor necrosis factor receptor superfamily member 8 (TNFRSF8) ELISA Kit (HUEB0329)
- SKU:
- HUEB0329
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P28908
- Range:
- 78-5000 pg/mL
- ELISA Type:
- Sandwich
- Synonyms:
- TNFRSF8, CD30, CD30 antigen, KI-1, CD30L receptor, cytokine receptor CD30, Ki-1 antigen, Lymphocyte activation antigen CD30, tumor necrosis factor receptor superfamily member 8
- Reactivity:
- Human
Description
Human Tumor necrosis factor receptor superfamily member 8 (TNFRSF8) ELISA Kit
The Human Tumor Necrosis Factor Receptor Superfamily Member 8 (TNFRSF8) ELISA Kit is specifically designed for the precise measurement of TNFRSF8 levels in human biological samples such as serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring accurate and consistent results, making it an invaluable tool for a variety of research purposes.TNFRSF8, also known as CD30, is a critical member of the tumor necrosis factor receptor superfamily, playing a key role in immune regulation and inflammation.
Aberrant expression of TNFRSF8 has been linked to various diseases, including cancer, autoimmune disorders, and infectious diseases, making it a promising target for therapeutic interventions.By utilizing the Human TNFRSF8 ELISA Kit, researchers can gain valuable insights into the role of TNFRSF8 in disease pathogenesis and progression, ultimately aiding in the development of novel diagnostic and therapeutic strategies. Stay ahead in your research with this advanced and reliable ELISA kit from Assay Genie.
Product Name: | Human Tumor necrosis factor receptor superfamily member 8 (TNFRSF8) ELISA Kit |
SKU: | HUEB0329 |
Size: | 96T |
Target: | Human Tumor necrosis factor receptor superfamily member 8 (TNFRSF8) |
Synonyms: | CD30L receptor, Ki-1 antigen, Lymphocyte activation antigen CD30, CD30, CD30, D1S166E |
Assay Type: | Sandwich |
Detection Method: | ELISA |
Reactivity: | Human |
Detection Range: | 78-5000pg/mL |
Sensitivity: | 21pg/mL |
Intra CV: | 6.8% | ||||||||||||||||||||
Inter CV: | 10.1% | ||||||||||||||||||||
Linearity: |
| ||||||||||||||||||||
Recovery: |
| ||||||||||||||||||||
Function: | Receptor for TNFSF8/CD30L. May play a role in the regulation of cellular growth and transformation of activated lymphoblasts. Regulates gene expression through activation of NF-kappa-B. |
Uniprot: | P28908 |
Sample Type: | Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids |
Specificity: | Natural and recombinant human Tumor necrosis factor receptor superfamily member 8 |
Sub Unit: | Interacts with TRAF1, TRAF2, TRAF3 and TRAF5. |
Research Area: | Immunology |
Subcellular Location: | Isoform 2 Cytoplasm |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | TNFRSF8: Receptor for TNFSF8/CD30L. May play a role in the regulation of cellular growth and transformation of activated lymphoblasts. Regulates gene expression through activation of NF- kappa-B. 2 isoforms of the human protein are produced by alternative initiation. |
UniProt Protein Details: | Protein type:Membrane protein, integral; Receptor, misc. Chromosomal Location of Human Ortholog: 1p36 Cellular Component: cytoplasm; integral to membrane; plasma membrane Molecular Function:transmembrane receptor activity Biological Process: positive regulation of tumor necrosis factor biosynthetic process; negative regulation of cell proliferation; positive regulation of apoptosis; positive regulation of TRAIL biosynthetic process; signal transduction |
NCBI Summary: | The protein encoded by this gene is a member of the TNF-receptor superfamily. This receptor is expressed by activated, but not by resting, T and B cells. TRAF2 and TRAF5 can interact with this receptor, and mediate the signal transduction that leads to the activation of NF-kappaB. This receptor is a positive regulator of apoptosis, and also has been shown to limit the proliferative potential of autoreactive CD8 effector T cells and protect the body against autoimmunity. Two alternatively spliced transcript variants of this gene encoding distinct isoforms have been reported. [provided by RefSeq, Jul 2008] |
UniProt Code: | P28908 |
NCBI GenInfo Identifier: | 115978 |
NCBI Gene ID: | 943 |
NCBI Accession: | P28908.1 |
UniProt Secondary Accession: | P28908,Q6P4D9, B1AN79, B9EGD9, D3YTD8, |
UniProt Related Accession: | P28908 |
Molecular Weight: | 50,935 Da |
NCBI Full Name: | Tumor necrosis factor receptor superfamily member 8 |
NCBI Synonym Full Names: | tumor necrosis factor receptor superfamily, member 8 |
NCBI Official Symbol: | TNFRSF8 |
NCBI Official Synonym Symbols: | CD30; Ki-1; D1S166E |
NCBI Protein Information: | tumor necrosis factor receptor superfamily member 8; Ki-1 antigen; CD30L receptor; cytokine receptor CD30; lymphocyte activation antigen CD30 |
UniProt Protein Name: | Tumor necrosis factor receptor superfamily member 8 |
UniProt Synonym Protein Names: | CD30L receptor; Ki-1 antigen; Lymphocyte activation antigen CD30; CD_antigen: CD30 |
UniProt Gene Name: | TNFRSF8 |
UniProt Entry Name: | TNR8_HUMAN |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |