Human Troponin T Type 1, Slow Skeletal (TNNT1) ELISA Kit
The Human Troponin T Type 1 (slow skeletal) (TNNT1) ELISA Kit is a highly sensitive and specific assay designed for the precise measurement of TNNT1 levels in human samples including serum, plasma, and cell culture supernatants. This kit is reliable and reproducible, offering accurate results for a variety of research applications.TNNT1 is a protein crucial for muscle contraction and is specifically found in slow skeletal muscle fibers. Abnormal levels of TNNT1 are associated with muscle disorders and myopathies, making it an important biomarker for studying these conditions and potential therapeutic interventions.
The Human Troponin T Type 1 (slow skeletal) (TNNT1) ELISA Kit is a valuable tool for researchers studying muscle-related diseases and looking to better understand the role of TNNT1 in muscle function. With its high sensitivity and specificity, this kit provides researchers with reliable data for their studies.
Product Name:
Human Troponin T Type 1, Slow Skeletal (TNNT1) ELISA Kit
Product Code:
HUDL02952
Size:
96 Assays
Target:
TNNT1
Synonyms:
ANM, STNT, TNT, TNTS, Slow Skeletal Muscle Troponin T
Detection Method:
Sandwich
Range:
15.625-1,000pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.