Human STXBP1 (Syntaxin-binding protein 1) ELISA Kit (HUFI06281)
- SKU:
- HUFI06281
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P61764
- Sensitivity:
- 0.094ng/ml
- Range:
- 0.156-10ng/ml
- ELISA Type:
- Sandwich
- Synonyms:
- EIEE4, MUNC18 1, N Sec1, p67, Protein unc 18 homolog 1, Protein unc 18 homolog A, RBSEC1, STXBP1, syntaxin binding protein 1, Unc 18A, UNC18, Unc18 1, UNC18A
- Reactivity:
- Human
Description
Human STXBP1 (Syntaxin-binding protein 1) ELISA Kit (HUFI06281)
The Human STXBP1 (Syntaxin Binding Protein 1) ELISA Kit is specifically designed to accurately measure levels of STXBP1 in human serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit ensures reliable and reproducible results, making it an excellent tool for various research applications.STXBP1 is a critical protein that plays a crucial role in regulating neurotransmitter release and synaptic function. Mutations in the STXBP1 gene have been associated with various neurological disorders, including epilepsy and intellectual disabilities.
Therefore, measuring STXBP1 levels can provide valuable insights into the pathogenesis of these disorders and aid in the development of potential therapeutic interventions.In summary, the Human STXBP1 ELISA Kit is a valuable tool for researchers studying synaptic transmission and neurological disorders associated with STXBP1 dysregulation. Its high performance and precision make it an indispensable asset in the field of neuroscience research.
Product Name: | Human STXBP1 (Syntaxin-binding protein 1) ELISA Kit |
Product Code: | HUFI06281 |
Size: | 96 Assays |
Alias: | EIEE4 ELISA Kit, MUNC18 1 ELISA Kit, N Sec1 ELISA Kit, p67 ELISA Kit, Protein unc 18 homolog 1 ELISA Kit, Protein unc 18 homolog A ELISA Kit, RBSEC1 ELISA Kit, STXBP1 ELISA Kit, syntaxin binding protein 1 ELISA Kit, Unc 18A ELISA Kit, UNC18 ELISA Kit, Unc18 1 ELISA Kit, UNC18A ELISA Kit |
Detection method: | Sandwich ELISA, Double Antibody |
Application: | This immunoassay kit allows for the in vitro quantitative determination of Human STXBP1 (Syntaxin-binding protein 1) concentrations in serum plasma and other biological fluids. |
Sensitivity: | < 0.094ng/ml |
Range: | 0.156-10ng/ml |
Storage: | 4°C for 6 months |
Note: | For Research Use Only |
Recovery: | Matrices listed below were spiked with certain level of Human STXBP1 (Syntaxin-binding protein 1) and the recovery rates were calculated by comparing the measured value to the expected amount of Human STXBP1 (Syntaxin-binding protein 1) in samples. Enquire for more information. |
Linearity: | The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human STXBP1 (Syntaxin-binding protein 1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. Enquire for more information. |
CV(%): | Intra-Assay: CV<8% Inter-Assay: CV<10% |
Component | Quantity | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | 4°C for 6 months |
Lyophilized Standard | 2 | 4°C/-20°C |
Sample/Standard Dilution Buffer | 20ml | 4°C |
Biotin-labeled Antibody(Concentrated) | 120ul | 4°C (Protect from light) |
Antibody Dilution Buffer | 10ml | 4°C |
HRP-Streptavidin Conjugate(SABC) | 120ul | 4°C (Protect from light) |
SABC Dilution Buffer | 10ml | 4°C |
TMB Substrate | 10ml | 4°C (Protect from light) |
Stop Solution | 10ml | 4°C |
Wash Buffer(25X) | 30ml | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
UniProt Protein Function: | STXBP1: may participate in the regulation of synaptic vesicle docking and fusion, possibly through interaction with GTP-binding proteins. Essential for neurotransmission and binds syntaxin, a component of the synaptic vesicle fusion machinery probably in a 1:1 ratio. Can interact with syntaxins 1, 2, and 3 but not syntaxin 4. May play a role in determining the specificity of intracellular fusion reactions. Two splice-variant isoforms have been described. |
UniProt Protein Details: | Protein type:Vesicle Chromosomal Location of Human Ortholog: 9q34.1 Cellular Component: cytoplasm; cytosol; mitochondrion; myelin sheath; nucleoplasm; plasma membrane; protein complex; terminal button Molecular Function:identical protein binding; protein binding; protein domain specific binding; protein kinase binding; protein N-terminus binding; SNARE binding; syntaxin binding; syntaxin-1 binding Biological Process: axon target recognition; energy reserve metabolic process; glutamate secretion; negative regulation of neuron apoptosis; negative regulation of synaptic transmission, GABAergic; neuromuscular synaptic transmission; neurotransmitter secretion; platelet degranulation; positive regulation of calcium ion-dependent exocytosis; protein stabilization; protein transport; regulation of insulin secretion; regulation of synaptic vesicle fusion to presynaptic membrane; synaptic transmission; synaptic vesicle maturation; vesicle docking during exocytosis Disease: Epileptic Encephalopathy, Early Infantile, 4 |
NCBI Summary: | This gene encodes a syntaxin-binding protein. The encoded protein appears to play a role in release of neurotransmitters via regulation of syntaxin, a transmembrane attachment protein receptor. Mutations in this gene have been associated with infantile epileptic encephalopathy-4. Alternatively spliced transcript variants have been described. [provided by RefSeq, Feb 2010] |
UniProt Code: | P61764 |
NCBI GenInfo Identifier: | 50403646 |
NCBI Gene ID: | 6812 |
NCBI Accession: | P61764.1 |
UniProt Secondary Accession: | P61764,Q28208, Q62759, Q64320, Q96TG8, B1AM97, |
UniProt Related Accession: | P61764 |
Molecular Weight: | 68,736 Da |
NCBI Full Name: | Syntaxin-binding protein 1 |
NCBI Synonym Full Names: | syntaxin binding protein 1 |
NCBI Official Symbol: | STXBP1 |
NCBI Official Synonym Symbols: | P67; NSEC1; UNC18; RBSEC1; MUNC18-1 |
NCBI Protein Information: | syntaxin-binding protein 1 |
UniProt Protein Name: | Syntaxin-binding protein 1 |
UniProt Synonym Protein Names: | MUNC18-1; N-Sec1; Protein unc-18 homolog 1; Unc18-1; Protein unc-18 homolog A; Unc-18A; p67 |
Protein Family: | Syntaxin-binding protein |
UniProt Gene Name: | STXBP1 |
UniProt Entry Name: | STXB1_HUMAN |
*Note: Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Before adding to wells, equilibrate the SABC working solution and TMB substrate for at least 30 min at 37 °C. When diluting samples and reagents, they must be mixed completely and evenly. It is recommended to plot a standard curve for each test.
Step | Protocol |
1. | Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample in duplicate. Wash plate 2 times before adding standard, sample and control (zero) wells! |
2. | Aliquot 0.1ml standard solutions into the standard wells. |
3. | Add 0.1 ml of Sample / Standard dilution buffer into the control (zero) well. |
4. | Add 0.1 ml of properly diluted sample ( Human serum, plasma, tissue homogenates and other biological fluids.) into test sample wells. |
5. | Seal the plate with a cover and incubate at 37 °C for 90 min. |
6. | Remove the cover and discard the plate content, clap the plate on the absorbent filter papers or other absorbent material. Do NOT let the wells completely dry at any time. Wash plate X2. |
7. | Add 0.1 ml of Biotin- detection antibody working solution into the above wells (standard, test sample & zero wells). Add the solution at the bottom of each well without touching the side wall. |
8. | Seal the plate with a cover and incubate at 37 °C for 60 min. |
9. | Remove the cover, and wash plate 3 times with Wash buffer. Let wash buffer rest in wells for 1 min between each wash. |
10. | Add 0.1 ml of SABC working solution into each well, cover the plate and incubate at 37 °C for 30 min. |
11. | Remove the cover and wash plate 5 times with Wash buffer, and each time let the wash buffer stay in the wells for 1-2 min. |
12. | Add 90 µL of TMB substrate into each well, cover the plate and incubate at 37 °C in dark within 10-20 min. (Note: This incubation time is for reference use only, the optimal time should be determined by end user.) And the shades of blue can be seen in the first 3-4 wells (with most concentrated standard solutions), the other wells show no obvious color. |
13. | Add 50 µL of Stop solution into each well and mix thoroughly. The color changes into yellow immediately. |
14. | Read the O.D. absorbance at 450 nm in a microplate reader immediately after adding the stop solution. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |