Human Structural maintenance of chromosomes protein 4 (SMC4) ELISA Kit (HUEB2408)
- SKU:
- HUEB2408
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- Q9NTJ3
- Range:
- 78-5000 pg/mL
- ELISA Type:
- Sandwich
- Synonyms:
- SMC4, Structural maintenance of chromosomes protein 4, SMC protein 4, SMC-4, Chromosome-associated polypeptide C, hCAP-C, XCAP-C homolog
- Reactivity:
- Human
Description
Human Structural maintenance of chromosomes protein 4 (SMC4) ELISA Kit
The Human Structural Maintenance of Chromosomes Protein 4 (SMC4) ELISA Kit is specifically designed for the accurate quantification of SMC4 levels in human serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring reliable and reproducible results for a variety of research applications.SMC4 is a vital protein involved in maintaining the structure of chromosomes during cell division, ensuring proper segregation of genetic material.
Dysregulation of SMC4 has been implicated in various diseases, including cancer and developmental disorders, making it a valuable biomarker for studying these conditions and potential therapeutic interventions.With its advanced technology and optimized assay protocols, the Human SMC4 ELISA Kit is an indispensable tool for researchers studying the role of SMC4 in health and disease. Get accurate and reliable results with this high-quality kit from Assay Genie.
Product Name: | Human Structural maintenance of chromosomes protein 4 (SMC4) ELISA Kit |
SKU: | HUEB2408 |
Size: | 96T |
Target: | Human Structural maintenance of chromosomes protein 4 (SMC4) |
Synonyms: | Chromosome-associated polypeptide C, XCAP-C homolog, hCAP-C, SMC protein 4, CAPC, SMC4L1 |
Assay Type: | Sandwich |
Detection Method: | ELISA |
Reactivity: | Human |
Detection Range: | 78-5000pg/mL |
Sensitivity: | 32pg/ml |
Intra CV: | 4.4% | ||||||||||||||||||||
Inter CV: | 9.2% | ||||||||||||||||||||
Linearity: |
| ||||||||||||||||||||
Recovery: |
| ||||||||||||||||||||
Function: | Central component of the condensin complex, a complex required for conversion of interphase chromatin into mitotic-like condense chromosomes. The condensin complex probably introduces positive supercoils into relaxed DNA in the presence of type I topoisomerases and converts nicked DNA into positive knotted forms in the presence of type II topoisomerases. |
Uniprot: | Q9NTJ3 |
Sample Type: | Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids |
Specificity: | Natural and recombinant human Structural maintenance of chromosomes protein 4 |
Sub Unit: | Forms a heterodimer with SMC2. Component of the condensin complex, which contains the SMC2 and SMC4 heterodimer, and three non SMC subunits that probably regulate the complex: BRRN1/CAPH, CNAP1/CAPD2 and CAPG. |
Research Area: | Cancer |
Subcellular Location: | Nucleus Cytoplasm Chromosome In interphase cells, the majority of the condensin complex is found in the cytoplasm, while a minority of the complex is associated with chromatin. A subpopulation of the complex however remains associated with chromosome foci in interphase cells. During mitosis, most of the condensin complex is associated with the chromatin. At the onset of prophase, the regulatory subunits of the complex are phosphorylated by CDC2, leading to condensin's association with chromosome arms and to chromosome condensation. Dissociation from chromosomes is observed in late telophase. |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | SMC4: Central component of the condensin complex, a complex required for conversion of interphase chromatin into mitotic-like condense chromosomes. The condensin complex probably introduces positive supercoils into relaxed DNA in the presence of type I topoisomerases and converts nicked DNA into positive knotted forms in the presence of type II topoisomerases. Forms an heterodimer with SMC2. Component of the condensin complex, which contains the SMC2 and SMC4 heterodimer, and three non SMC subunits that probably regulate the complex: BRRN1/CAPH, CNAP1/CAPD2 and CAPG. Widely expressed. Higher expression in testis, colon, thymus. Belongs to the SMC family. SMC4 subfamily. 2 isoforms of the human protein are produced by alternative splicing. |
UniProt Protein Details: | Protein type:Cell cycle regulation Chromosomal Location of Human Ortholog: 3q26.1 Cellular Component: nucleoplasm; cytoplasm; condensin complex; cytosol; nucleus Molecular Function:protein binding; protein heterodimerization activity; ATP binding Biological Process: mitotic sister chromatid segregation; meiotic chromosome condensation; mitotic chromosome condensation; cell division; mitotic cell cycle; kinetochore organization and biogenesis; meiotic chromosome segregation |
NCBI Summary: | This gene belongs to the 'structural maintenance of chromosomes' (SMC) gene family. Members of this gene family play a role in two changes in chromosome structure during mitotic segregation of chromosomes- chromosome condensation and sister chromatid cohesion. The protein encoded by this gene is likely a subunit of the 13S condensin complex, which is involved in chromosome condensation. A pseudogene related to this gene is located on chromosome 2. [provided by RefSeq, Jun 2016] |
UniProt Code: | Q9NTJ3 |
NCBI GenInfo Identifier: | 50658065 |
NCBI Gene ID: | 10051 |
NCBI Accession: | NP_005487.3 |
UniProt Related Accession: | Q9NTJ3 |
Molecular Weight: | Observed: 150 kDaPredicted: 148 kDa |
NCBI Full Name: | structural maintenance of chromosomes protein 4 isoform 1 |
NCBI Synonym Full Names: | structural maintenance of chromosomes 4 |
NCBI Official Symbol: | SMC4 |
NCBI Official Synonym Symbols: | CAPC; CAP-C; SMC-4; SMC4L1 |
NCBI Protein Information: | structural maintenance of chromosomes protein 4 |
UniProt Protein Name: | Structural maintenance of chromosomes protein 4 |
UniProt Synonym Protein Names: | Chromosome-associated polypeptide C; hCAP-C; XCAP-C homolog |
Protein Family: | Structural maintenance of chromosomes protein |
UniProt Gene Name: | SMC4 |
UniProt Entry Name: | SMC4_HUMAN |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |
ELISA |
Human SMC4 ELISA Kit |