The Human Sialidase 2 (Cytosolic Sial2) ELISA Kit is a powerful tool for the quantitative measurement of sialidase 2 levels in human samples such as serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity, allowing for accurate and reliable results that are essential for a variety of research applications.Sialidase 2, also known as NEU2, is an enzyme involved in the hydrolysis of sialic acids, playing a crucial role in various cellular processes including cell adhesion, migration, and signaling. Dysregulation of sialidase 2 has been implicated in diseases such as cancer, metabolic disorders, and inflammatory conditions, highlighting its significance as a potential biomarker for disease detection and monitoring.
By using the Human Sialidase 2 ELISA Kit, researchers can gain valuable insights into the role of sialidase 2 in disease pathogenesis and progression, paving the way for the development of targeted therapies and treatment strategies. Trust in the accuracy and precision of this ELISA kit to advance your research efforts in understanding the complex mechanisms of sialidase 2 biology.
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.