Human Semaphorin 3B / SEMA3B ELISA Kit
- SKU:
- HUFI01855
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- Q13214
- Sensitivity:
- 0.938ng/ml
- Range:
- 1.563-100ng/ml
- ELISA Type:
- Sandwich
- Synonyms:
- SEMA3B, LUCA-1, SEMA3B, SEMA5, SEMAA, SEMAV, semaphorin 3B, LUCA-1, SemA, Sema A, V, sema domain, immunoglobulin domain, Ig, short basic domain, secreted, Sema V, sema5, SEMA5, SEMAA, semaphorin A, semaphorin V, semaphorin-3B, Semaphorin-V, semaphori
- Reactivity:
- Human
- Research Area:
- Cell Biology
Description
Human Semaphorin 3B/SEMA3B ELISA Kit
The Human SEMA3B (Semaphorin 3B) ELISA Kit is specifically designed for the precise quantification of SEMA3B levels in human serum, plasma, and cell culture supernatants. With exceptional sensitivity and specificity, this kit delivers accurate and consistent results, making it an invaluable tool for a diverse range of research applications.SEMA3B is a critical protein involved in cell signaling and tissue development, playing a key role in regulating cell migration and axon guidance. Dysregulation of SEMA3B expression has been linked to various diseases, including cancer, neurological disorders, and cardiovascular conditions, making it a valuable biomarker for studying these diseases and exploring potential therapeutic interventions.
By utilizing the Human SEMA3B ELISA Kit, researchers can gain valuable insights into SEMA3B levels, furthering our understanding of its role in disease progression and facilitating the development of targeted treatments. Trust in the accuracy and reliability of this ELISA kit to advance your research endeavors in the field of SEMA3B biology.
Product Name: | Human Semaphorin 3B / SEMA3B ELISA Kit |
Product Code: | HUFI01855 |
Size: | 96 Assays |
Alias: | SEMA3B, LUCA-1, SEMA3B, SEMA5, SEMAA, SEMAV, semaphorin 3B, LUCA-1, SemA, Sema A, V, sema domain, immunoglobulin domain, Ig, short basic domain, secreted, Sema V, sema5, SEMA5, SEMAA, semaphorin A, semaphorin V, semaphorin-3B, Semaphorin-V, semaphorin-V, semaV, Sema A, V, Semaphorin-V, Sema V |
Detection method: | Sandwich ELISA, Double Antibody |
Application: | This immunoassay kit allows for the in vitro quantitative determination of Human SEMA3B concentrations in serum plasma and other biological fluids. |
Sensitivity: | 0.938ng/ml |
Range: | 1.563-100ng/ml |
Storage: | 4°C for 6 months |
Note: | For Research Use Only |
Recovery: | Matrices listed below were spiked with certain level of Human SEMA3B and the recovery rates were calculated by comparing the measured value to the expected amount of Human SEMA3B in samples. | ||||||||||||||||
| |||||||||||||||||
Linearity: | The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human SEMA3B and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. | ||||||||||||||||
| |||||||||||||||||
CV(%): | Intra-Assay: CV<8% Inter-Assay: CV<10% |
Component | Quantity | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | 4°C for 6 months |
Lyophilized Standard | 2 | 4°C/-20°C |
Sample/Standard Dilution Buffer | 20ml | 4°C |
Biotin-labeled Antibody(Concentrated) | 120ul | 4°C (Protect from light) |
Antibody Dilution Buffer | 10ml | 4°C |
HRP-Streptavidin Conjugate(SABC) | 120ul | 4°C (Protect from light) |
SABC Dilution Buffer | 10ml | 4°C |
TMB Substrate | 10ml | 4°C (Protect from light) |
Stop Solution | 10ml | 4°C |
Wash Buffer(25X) | 30ml | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
Uniprot | Q13214 |
UniProt Protein Function: | SEMA3B: Inhibits axonal extension by providing local signals to specify territories inaccessible for growing axons. Expressed abundantly but differentially in a variety of neural and nonneural tissues. Belongs to the semaphorin family. 2 isoforms of the human protein are produced by alternative splicing. |
UniProt Protein Details: | Protein type:Secreted, signal peptide; Motility/polarity/chemotaxis; Cell development/differentiation; Secreted Chromosomal Location of Human Ortholog: 3p21.3 Cellular Component: membrane; endoplasmic reticulum Molecular Function:receptor activity Biological Process: axon guidance; cell-cell signaling |
NCBI Summary: | The protein encoded by this gene belongs to the class-3 semaphorin/collapsin family, whose members function in growth cone guidance during neuronal development. This family member inhibits axonal extension and has been shown to act as a tumor suppressor by inducing apoptosis. Alternative splicing of this gene results in multiple transcript variants. [provided by RefSeq, Feb 2014] |
UniProt Code: | Q13214 |
NCBI GenInfo Identifier: | 8134673 |
NCBI Gene ID: | 7869 |
NCBI Accession: | Q13214.1 |
UniProt Secondary Accession: | Q13214,Q6GU46, Q8TB71, Q8TDV7, Q93018, Q96GX0, |
UniProt Related Accession: | Q13214 |
Molecular Weight: | 749 |
NCBI Full Name: | Semaphorin-3B |
NCBI Synonym Full Names: | sema domain, immunoglobulin domain (Ig), short basic domain, secreted, (semaphorin) 3B |
NCBI Official Symbol: | SEMA3B |
NCBI Official Synonym Symbols: | SemA; SEMA5; SEMAA; semaV; LUCA-1 |
NCBI Protein Information: | semaphorin-3B; sema A(V); semaphorin A; semaphorin-V |
UniProt Protein Name: | Semaphorin-3B |
UniProt Synonym Protein Names: | Sema A(V); Semaphorin-V; Sema V |
Protein Family: | Semaphorin |
UniProt Gene Name: | SEMA3B |
UniProt Entry Name: | SEM3B_HUMAN |
*Note: Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Before adding to wells, equilibrate the SABC working solution and TMB substrate for at least 30 min at 37°C. When diluting samples and reagents, they must be mixed completely and evenly. It is recommended to plot a standard curve for each test.
Step | Protocol |
1. | Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample in duplicate. Wash plate 2 times before adding standard, sample and control (zero) wells! |
2. | Aliquot 0.1ml standard solutions into the standard wells. |
3. | Add 0.1 ml of Sample / Standard dilution buffer into the control (zero) well. |
4. | Add 0.1 ml of properly diluted sample ( Human serum, plasma, tissue homogenates and other biological fluids.) into test sample wells. |
5. | Seal the plate with a cover and incubate at 37 °C for 90 min. |
6. | Remove the cover and discard the plate content, clap the plate on the absorbent filter papers or other absorbent material. Do NOT let the wells completely dry at any time. Wash plate X2. |
7. | Add 0.1 ml of Biotin- detection antibody working solution into the above wells (standard, test sample & zero wells). Add the solution at the bottom of each well without touching the side wall. |
8. | Seal the plate with a cover and incubate at 37°C for 60 min. |
9. | Remove the cover, and wash plate 3 times with Wash buffer. Let wash buffer rest in wells for 1 min between each wash. |
10. | Add 0.1 ml of SABC working solution into each well, cover the plate and incubate at 37°C for 30 min. |
11. | Remove the cover and wash plate 5 times with Wash buffer, and each time let the wash buffer stay in the wells for 1-2 min. |
12. | Add 90 µl of TMB substrate into each well, cover the plate and incubate at 37°C in dark within 10-20 min. (Note: This incubation time is for reference use only, the optimal time should be determined by end user.) And the shades of blue can be seen in the first 3-4 wells (with most concentrated standard solutions), the other wells show no obvious color. |
13. | Add 50 µl of Stop solution into each well and mix thoroughly. The color changes into yellow immediately. |
14. | Read the O.D. absorbance at 450 nm in a microplate reader immediately after adding the stop solution. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |