Human Rho Associated Coiled Coil Containing Protein Kinase 1 (Rock1) ELISA Kit
The Human Rho-Associated Coiled-Coil Containing Protein Kinase 1 (ROCK1) ELISA Kit is a highly accurate tool for measuring ROCK1 levels in human samples such as serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit provides reliable and reproducible results, making it suitable for various research applications.ROCK1 is a key protein involved in cell migration, cell adhesion, and cytoskeleton dynamics.
It has been implicated in various diseases such as cancer, cardiovascular disorders, and neurological conditions, making it a valuable biomarker for studying these diseases and developing potential treatments.By utilizing the Human ROCK1 ELISA Kit, researchers can gain valuable insights into the role of ROCK1 in disease pathology and potentially identify novel therapeutic targets. Don't miss out on this essential tool for your research needs.
Product Name:
Human Rho Associated Coiled Coil Containing Protein Kinase 1 (Rock1) ELISA Kit
Product Code:
HUDL02556
Size:
96 Assays
Target:
Rock1
Synonyms:
p160ROCK, Rho-associated protein kinase 1, Renal carcinoma antigen NY-REN-35
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
87-100
93
EDTA plasma (n=5)
89-99
94
Heparin plasma (n=5)
90-98
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.