Human Neuropeptide Y Receptor Y2 (NPY2R) ELISA Kit
The Human Neuropeptide Y Receptor Y2 (NPY2R) ELISA Kit is a reliable and accurate tool for detecting levels of NPY2R in human samples such as serum, plasma, and cell culture supernatants. This kit boasts high sensitivity and specificity, ensuring precise and reproducible results for a variety of research applications.NPY2R is a key receptor involved in the regulation of neuropeptide Y, which plays a crucial role in various physiological and pathological processes, including appetite regulation, stress response, and cardiovascular function. Dysregulation of NPY2R has been implicated in conditions such as obesity, anxiety disorders, and cardiovascular diseases, making it a valuable biomarker for studying these disorders and potentially developing targeted therapies.
By using the Human NPY2R ELISA Kit, researchers can accurately measure NPY2R levels in human samples, providing valuable insights into the role of this receptor in health and disease. With its high performance and ease of use, this kit is an indispensable tool for advancing research in the field of neuropeptide Y signaling.
Product Name:
Human Neuropeptide Y Receptor Y2 (NPY2R) ELISA Kit
Product Code:
HUDL02081
Size:
96 Assays
Target:
NPY2R
Synonyms:
NPY-Y2 receptor
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
90-103
96
Heparin plasma (n=5)
90-99
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.