The Human Myostatin (MSTN) ELISA Kit is a reliable and sensitive tool for detecting levels of myostatin in human biological samples such as serum, plasma, and cell culture supernatants. Myostatin is a key regulator of muscle growth and development, making it an important target for research in various fields including exercise physiology, muscle wasting conditions, and muscle-related disorders.This ELISA kit offers high specificity and accuracy, ensuring precise and reproducible results for your research needs.
By measuring myostatin levels, researchers can gain valuable insights into the factors influencing muscle mass and strength, leading to advancements in the treatment of muscle-related conditions and the development of potential therapeutic interventions.Overall, the Human Myostatin (MSTN) ELISA Kit from Assay Genie provides a valuable tool for studying the role of myostatin in human physiology and disease, offering reliable data for a wide range of research applications.
Product Name:
Human Myostatin (MSTN) ELISA Kit
Product Code:
HUDL01913
Size:
96 Assays
Target:
MSTN
Synonyms:
GDF8, Growth Differentiation Factor 8
Detection Method:
Sandwich
Range:
0.781-50ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.