Human Latent Transforming Growth Factor Beta Binding Protein 2 (LTBP2) ELISA Kit
The Human Latent Transforming Growth Factor Beta Binding Protein 2 (LTBP2) ELISA Kit is specifically designed for the precise and reliable detection of LTBP2 levels in human serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit ensures accurate and reproducible results, making it an ideal tool for a wide range of research applications.LTBP2 is a key protein involved in the regulation of transforming growth factor beta (TGF-β) signaling, playing a crucial role in various biological processes such as cell growth, differentiation, and tissue development.
Dysregulation of LTBP2 has been implicated in numerous diseases, including fibrosis, cancer, and developmental disorders, making it a valuable biomarker for studying these conditions and exploring potential therapeutic interventions.Overall, the Human LTBP2 ELISA Kit offers researchers a valuable tool for investigating the role of LTBP2 in various biological processes and diseases, providing valuable insights into potential diagnostic and therapeutic strategies.
Product Name:
Human Latent Transforming Growth Factor Beta Binding Protein 2 (LTBP2) ELISA Kit
Product Code:
HUDL01766
Size:
96 Assays
Target:
LTBP2
Synonyms:
C14orf141, LTBP3
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.