The Human Karyopherin Alpha 2 (KPNA2) ELISA Kit is a specialized tool for the precise measurement of KPNA2 levels in human samples including serum, plasma, and cell culture supernatants. With its exceptional sensitivity and specificity, this kit offers reliable and reproducible results, making it an invaluable asset for a wide range of research studies.KPNA2 is a key player in the regulation of nucleocytoplasmic transport, mediating the transportation of proteins in and out of the cell nucleus. Dysregulation of KPNA2 has been linked to various diseases including cancer, autoimmune disorders, and viral infections, underscoring its importance as a potential therapeutic target and diagnostic marker.
By using the Human Karyopherin Alpha 2 (KPNA2) ELISA Kit, researchers can gain valuable insights into the role of KPNA2 in disease pathogenesis and explore its potential as a target for novel treatment strategies. This kit is easy to use and delivers accurate results, making it an essential tool for advancing research in the field of nucleocytoplasmic transport and its implications in human health and disease.
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.