The Human Interleukin-34 (IL-34) ELISA Kit is a powerful tool for the precise measurement of IL-34 levels in human samples such as serum, plasma, and cell culture supernatants. This kit is known for its exceptional sensitivity and specificity, guaranteeing consistent and accurate results for a diverse range of research purposes.Interleukin-34 is a vital cytokine that plays a key role in regulating immune responses and inflammation. It is implicated in various diseases and conditions, including cancer, autoimmune disorders, and inflammatory diseases.
The detection of IL-34 levels can provide valuable insights into the pathogenesis of these conditions and aid in the development of targeted therapies.With its reliable performance and broad utility, the Human Interleukin-34 (IL-34) ELISA Kit is an indispensable tool for researchers seeking to unravel the complex mechanisms of immune regulation and inflammation. Trust this kit to deliver precise and consistent results, driving advancements in biomedical research and clinical diagnostics.
Product Name:
Human Interleukin 34 (IL-34) ELISA Kit
Product Code:
HUDL01514
Size:
96 Assays
Target:
IL34
Synonyms:
C16orf77
Detection Method:
Sandwich
Range:
15.625-1000pg/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
91-98
94
Heparin plasma (n=5)
90-99
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.