Human Inter Alpha-Globulin Inhibitor H5 (ITIH5) ELISA Kit
The Human Inter-Alpha Globulin Inhibitor H5 (ITIH5) ELISA Kit is a highly reliable and accurate tool for the detection of ITIH5 levels in human serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring precise and reproducible results for a variety of research applications.ITIH5 is a critical protein involved in the regulation of inflammatory and immune responses, making it an important biomarker for studying conditions related to these processes.
By detecting ITIH5 levels, researchers can gain valuable insights into diseases such as cancer, inflammatory disorders, and autoimmune diseases, leading to a better understanding of their mechanisms and potential therapeutic interventions.Overall, the Human ITIH5 ELISA Kit is a valuable tool for researchers looking to investigate the role of ITIH5 in disease pathology and explore its potential as a target for novel treatment strategies.
Product Name:
Human Inter Alpha-Globulin Inhibitor H5 (ITIH5) ELISA Kit
Product Code:
HUDL01579
Size:
96 Assays
Target:
ITIH5
Synonyms:
Inter-alpha-trypsin inhibitor heavy chain H5
Detection Method:
Sandwich
Range:
78.12-5,000ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.