Human High Mobility Group AT Hook Protein 2 (HMGA2) ELISA Kit
The Human High Mobility Group AT-Hook Protein 2 (HMGA2) ELISA Kit is a reliable and accurate tool for the detection of HMGA2 levels in human samples including serum, plasma, and cell culture supernatants. This kit is designed with high sensitivity and specificity, ensuring precise and reproducible results for a variety of research applications.HMGA2 is a critical protein involved in regulating gene expression and playing a role in various cellular processes such as cell growth, proliferation, and differentiation.
Dysregulation of HMGA2 has been linked to cancer, diabetes, and other diseases, highlighting its importance as a potential biomarker for disease diagnosis and therapeutic development.By using the Human HMGA2 ELISA Kit, researchers can gain valuable insights into the role of HMGA2 in disease pathogenesis and progression, ultimately contributing to the development of novel targeted therapies and personalized medicine approaches.
Product Name:
Human High Mobility Group AT Hook Protein 2 (HMGA2) ELISA Kit
Product Code:
HUDL01342
Size:
96 Assays
Target:
HMGA2
Synonyms:
BABL, HMGI-C, HMGIC, LIPO, High mobility group protein HMGI-C
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.