Human GLP1R (Glucagon-like Peptide 1 receptor) ELISA Kit (HUES03358)
- SKU:
- HUES03358
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P43220
- Sensitivity:
- 0.19ng/mL
- Range:
- 0.31-20ng/mL
- ELISA Type:
- Sandwich
- Reactivity:
- Human
- Sample Type:
- Serum, plasma and other biological fluids
- Research Area:
- Cell Biology
Description
Human GLP1R (Glucagon-like Peptide 1 receptor) ELISA Kit
The Human GLP-1R (Glucagon-like Peptide-1 Receptor) ELISA Kit is a powerful tool for quantifying GLP-1R levels in human samples including serum, plasma, and cell culture supernatants. With its exceptional sensitivity and specificity, this kit delivers accurate and reproducible results, making it an invaluable resource for a variety of research applications.GLP-1R is a key receptor involved in mediating the effects of glucagon-like peptide-1, a hormone crucial in regulating glucose metabolism and insulin secretion. Dysregulation of GLP-1R signaling has been implicated in diabetes, obesity, and other metabolic disorders, underscoring the importance of studying this receptor in both basic research and drug development efforts.
Whether investigating GLP-1R function in disease pathogenesis or evaluating the efficacy of potential therapeutic interventions, the Human GLP-1R ELISA Kit provides a reliable and efficient means of quantifying GLP-1R levels, offering insights that can advance our understanding of metabolic disorders and aid in the development of novel treatments.
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Human |
Detection Method: | Colormetric |
Detection Range: | 0.31-20 ng/mL |
Sensitivity: | 0.19 ng/mL |
Sample Volume Required Per Well: | 100µL |
Sample Type: | Serum, plasma and other biological fluids |
Specificity: | This kit recognizes Human GLP1R in samples. No significant cross-reactivity or interference between Human GLP1R and analogues was observed. |
This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human GLP1R. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GLP1R and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GLP1R, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by adding Stop Solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human GLP1R. The concentration of Human GLP1R in samples can be calculated by comparing the OD of the samples to the standard curve.
UniProt Protein Function: | GLP1R: This is a receptor for glucagon-like peptide 1. The activity of this receptor is mediated by G proteins which activate adenylyl cyclase. Belongs to the G-protein coupled receptor 2 family. |
UniProt Protein Details: | Protein type:Membrane protein, multi-pass; Membrane protein, integral; Receptor, GPCR; GPCR, family 2 Chromosomal Location of Human Ortholog: 6p21 Cellular Component: cytosol; integral to membrane; intracellular; plasma membrane Molecular Function:glucagon receptor activity; protein binding; transmembrane receptor activity Biological Process: adenylate cyclase activation; cAMP-mediated signaling; cell surface receptor linked signal transduction; elevation of cytosolic calcium ion concentration; energy reserve metabolic process; G-protein coupled receptor protein signaling pathway; learning and/or memory; positive regulation of blood pressure; regulation of heart contraction; regulation of insulin secretion; response to stress |
NCBI Summary: | This gene encodes a 7-transmembrane protein that functions as a receptor for glucagon-like peptide 1 (GLP-1) hormone, which stimulates glucose-induced insulin secretion. This receptor, which functions at the cell surface, becomes internalized in response to GLP-1 and GLP-1 analogs, and it plays an important role in the signaling cascades leading to insulin secretion. It also displays neuroprotective effects in animal models. Polymorphisms in this gene are associated with diabetes. The protein is an important drug target for the treatment of type 2 diabetes and stroke. Alternative splicing of this gene results in multiple transcript variants. [provided by RefSeq, Apr 2016] |
UniProt Code: | P43220 |
NCBI GenInfo Identifier: | 311033387 |
NCBI Gene ID: | 2740 |
NCBI Accession: | P43220. 2 |
UniProt Secondary Accession: | P43220,Q2M229, Q99669, |
UniProt Related Accession: | P43220 |
Molecular Weight: | |
NCBI Full Name: | Glucagon-like peptide 1 receptor |
NCBI Synonym Full Names: | glucagon like peptide 1 receptor |
NCBI Official Symbol: | GLP1R |
NCBI Official Synonym Symbols: | GLP-1; GLP-1R; GLP-1-R |
NCBI Protein Information: | glucagon-like peptide 1 receptor |
UniProt Protein Name: | Glucagon-like peptide 1 receptor |
Protein Family: | Glucagon-like peptide 1 receptor |
UniProt Gene Name: | GLP1R |
UniProt Entry Name: | GLP1R_HUMAN |
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (ng/mL) | O.D | Average | Corrected |
20 | 2.4 2.436 | 2.418 | 2.359 |
10 | 1.55 1.552 | 1.551 | 1.492 |
5 | 0.946 0.934 | 0.94 | 0.881 |
2.5 | 0.386 0.418 | 0.402 | 0.343 |
1.25 | 0.262 0.246 | 0.254 | 0.195 |
0.63 | 0.16 0.156 | 0.158 | 0.099 |
0.31 | 0.106 0.112 | 0.109 | 0.05 |
0 | 0.053 0.065 | 0.059 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human GLP1R were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human GLP1R were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 1.07 | 2.25 | 6.85 | 1.16 | 2.05 | 6.99 |
Standard deviation | 0.06 | 0.13 | 0.37 | 0.06 | 0.12 | 0.30 |
C V (%) | 5.61 | 5.78 | 5.40 | 5.17 | 5.85 | 4.29 |
Recovery
The recovery of Human GLP1R spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 85-98 | 92 |
EDTA plasma (n=5) | 92-108 | 98 |
Cell culture media (n=5) | 87-101 | 92 |
Linearity
Samples were spiked with high concentrations of Human GLP1R and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 93-106 | 88-100 | 92-105 |
Average (%) | 98 | 94 | 98 | |
1:4 | Range (%) | 90-106 | 83-94 | 80-92 |
Average (%) | 97 | 88 | 87 | |
1:8 | Range (%) | 87-98 | 86-100 | 88-101 |
Average (%) | 93 | 92 | 94 | |
1:16 | Range (%) | 91-104 | 80-93 | 82-93 |
Average (%) | 99 | 86 | 88 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro ELISA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 4°C(shading light) |
Stop Solution | 1 vial, 10 mL | 4°C |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100µl of standard solutions into the standard wells.
- Add 100µl of Sample / Standard dilution buffer into the control (zero) well.
- Add 100µl of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37°C.
- Aspirate the liquid from each well, do not wash. Immediately add 100µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37°C.
- Aspirate or decant the solution from the plate and add 350µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37°C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 90µL of Substrate Reagent to each well. Cover with a new plate seal and incubate forapproximately 15 min at 37°C. Protect the plate from light. Note: the reaction time can beshortened or extended according to the actual color change, but not by more than 30min.
- Add 50 µL of Stop Solution to each well. Note: Adding the stop solution should be done inthe same order as the substrate solution.
- Determine the optical density (OD value) of each well immediately with a microplate readerset at 450 nm.