Human GLI Family Zinc Finger Protein 1 (GLI1) ELISA Kit
The Human GLI Family Zinc Finger Protein 1 (GLI1) ELISA Kit, researchers can expect accurate detection of GLI1 levels in human samples such as serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity, guaranteeing reliable and consistent results for various research purposes.GLI1 is a key transcription factor in the Hedgehog signaling pathway, playing a critical role in cell development and proliferation.
Dysregulation of GLI1 is associated with various diseases including cancer, making it a valuable biomarker for studying disease mechanisms and potential therapeutic interventions.Overall, the Human GLI1 ELISA Kit is a valuable tool for researchers seeking to investigate the implications of GLI1 in various physiological and pathological processes, providing accurate and reliable data for in-depth analysis and interpretation.
Product Name:
Human GLI Family Zinc Finger Protein 1 (GLI1) ELISA Kit
Product Code:
HUDL01197
Size:
96 Assays
Target:
GLI1
Synonyms:
Glioma-Associated Oncogene Family Zinc Finger 1
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.