The Human Connexin 37 (Cx37) ELISA Kit is a powerful tool for researchers looking to measure Connexin 37 levels in human samples. Connexin 37 is a crucial protein involved in cell-to-cell communication, with implications in various biological processes such as vascular development, endothelial function, and cardiac electrophysiology.This ELISA kit offers high sensitivity and specificity, ensuring accurate and reproducible results in serum, plasma, and cell culture supernatants.
By accurately quantifying Connexin 37 levels, researchers can gain valuable insights into its role in various physiological and pathological conditions, including cardiovascular diseases, diabetes, and cancer.Whether studying vascular biology, cell signaling, or disease mechanisms, the Human Connexin 37 (Cx37) ELISA Kit is a valuable tool for researchers seeking to unravel the complexities of Connexin 37 biology and its potential therapeutic implications.
Product Name:
Human Connexin 37 (CX37) ELISA Kit
Product Code:
HUDL00741
Size:
96 Assays
Target:
CX37
Synonyms:
GJA4, GJ-A4, Gap Junction Protein Alpha 4
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
91-98
94
Heparin plasma (n=5)
90-99
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.