Human CMRF35-like molecule 7 (CD300LB) ELISA Kit (HUEB1341)
- SKU:
- HUEB1341
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- A8K4G0
- Range:
- 78-5000 pg/mL
- ELISA Type:
- Sandwich
- Synonyms:
- CD300LB, CMRF35-like molecule 7, CLM-7
- Reactivity:
- Human
Description
Human CMRF35-like molecule 7 (CD300LB) ELISA Kit
The Human CMRF35-Like Molecule 7 (CD300LB) ELISA Kit is specifically designed for the accurate detection of CD300LB levels in human serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity, ensuring reliable and reproducible results for a variety of research applications.CD300LB, also known as CMRF35-like molecule 7, is a cell surface receptor that plays a role in regulating immune responses and may be involved in various disease processes.
By accurately measuring CD300LB levels, researchers can gain valuable insights into its functions and potential implications in conditions such as autoimmune diseases, inflammation, and cancer.With easy-to-follow protocols and high-quality components, the Human CMRF35-Like Molecule 7 (CD300LB) ELISA Kit is a valuable tool for studying the roles of CD300LB in health and disease, paving the way for future therapeutic developments and advancements in biomedical research.
Product Name: | Human CMRF35-like molecule 7 (CD300LB) ELISA Kit |
SKU: | HUEB1341 |
Size: | 96T |
Target: | Human CMRF35-like molecule 7 (CD300LB) |
Synonyms: | CD300 antigen-like family member B, CMRF35-A2, Immune receptor expressed on myeloid cells 3, Leukocyte mono-Ig-like receptor 5, Triggering receptor expressed on myeloid cells 5, IREM-3, TREM-5, CD300b, UNQ2530/PRO6029, CLM-7, CD300B, CLM7, CMRF35A2, IREM3, LMIR5, TREM5 |
Assay Type: | Sandwich |
Detection Method: | ELISA |
Reactivity: | Human |
Detection Range: | 78-5000pg/mL |
Sensitivity: | 39pg/ml |
Intra CV: | 5.2% | ||||||||||||||||||||
Inter CV: | 10.3% | ||||||||||||||||||||
Linearity: |
| ||||||||||||||||||||
Recovery: |
| ||||||||||||||||||||
Function: | Acts as an activating immune receptor through its interaction with ITAM-bearing adapter TYROBP, and also independently by recruitment of GRB2. |
Uniprot: | A8K4G0 |
Sample Type: | Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids |
Specificity: | Natural and recombinant human CMRF35-like molecule 7 |
Sub Unit: | Interacts with TYROBP, which enhances cell surface expression and activation properties. Interacts with GRB2 in the presence of FYN. |
Research Area: | Immunology |
Subcellular Location: | Cell membrane Single-pass type I membrane protein |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | Function: Acts as an activating immune receptor through its interaction with ITAM-bearing adapter TYROBP, and also independently by recruitment of GRB2. Ref.1 Ref.9 |
UniProt Protein Details: | Subunit structure: Interacts with TYROBP, which enhances cell surface expression and activation properties. Interacts with GRB2 in the presence of FYN. Ref.1 Ref.9 Subcellular location: Cell membrane; Single-pass type I membrane protein By similarity. Tissue specificity: Expressed exclusively in myeloid lineages. Ref.1 Post-translational modification: Phosphorylation on Tyr-188 by FYN is required for interaction with GRB2. Sequence similarities: Belongs to the CD300 family.Contains 1 Ig-like V-type (immunoglobulin-like) domain. Sequence caution: The sequence AAH28091.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally shortened.The sequence BAF83614.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally shortened.The sequence EAW89170.1 differs from that shown. Reason: Erroneous initiation. Translation N-terminally shortened. |
NCBI Summary: | CD300LB is a nonclassical activating receptor of the immunoglobulin (Ig) superfamily expressed on myeloid cells (Martinez-Barriocanal and Sayos, 2006 [PubMed 16920917]).[supplied by OMIM, Mar 2008] |
UniProt Code: | A8K4G0 |
NCBI GenInfo Identifier: | 510936990 |
NCBI Gene ID: | 124599 |
NCBI Accession: | NP_777552.3 |
UniProt Secondary Accession: | A8K4G0,Q1EG73, Q8IX40, Q8N6D1, |
UniProt Related Accession: | A8K4G0 |
Molecular Weight: | 22,689 Da |
NCBI Full Name: | CMRF35-like molecule 7 |
NCBI Synonym Full Names: | CD300 molecule-like family member b |
NCBI Official Symbol: | CD300LB |
NCBI Official Synonym Symbols: | CLM7; CLM-7; IREM3; TREM5; CD300b; IREM-3; TREM-5; CMRF35-A2 |
NCBI Protein Information: | CMRF35-like molecule 7; leukocyte mono-Ig-like receptor 5; CD300 antigen like family member B; immune receptor expressed on myeloid cells 3; triggering receptor expressed on myeloid cells 5 |
UniProt Protein Name: | CMRF35-like molecule 7 |
UniProt Synonym Protein Names: | CD300 antigen-like family member B; CMRF35-A2; Immune receptor expressed on myeloid cells 3; IREM-3; Leukocyte mono-Ig-like receptor 5; Triggering receptor expressed on myeloid cells 5 |
Protein Family: | CMRF35-like molecule |
UniProt Gene Name: | CD300LB |
UniProt Entry Name: | CLM7_HUMAN |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |