Human C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ELISA Kit
The Human C1q and Tumor Necrosis Factor-Related Protein 9 (C1QTNF9) ELISA Kit is a specialized assay designed for the precise measurement and analysis of C1QTNF9 levels in human biological samples such as serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring accurate and reproducible results for a variety of research applications. C1QTNF9, a member of the C1q/TNF-related protein family, plays a critical role in various physiological processes, including metabolism, inflammation, and adipogenesis.
Dysregulation of C1QTNF9 has been linked to metabolic disorders, such as obesity and diabetes, as well as inflammatory conditions. As a key biomarker in these diseases, the Human C1QTNF9 ELISA Kit provides researchers with a valuable tool for studying the pathogenesis of these disorders and potential therapeutic interventions.
Product Name:
Human C1q And Tumor Necrosis Factor Related Protein 9 (C1QTNF9) ELISA Kit
Product Code:
HUDL00373
Size:
96 Assays
Target:
C1QTNF9
Synonyms:
CTRP9, C1QTNF9A, AQL1, Complement C1q and tumor necrosis factor-related protein 9A
Detection Method:
Sandwich
Range:
3.125-200ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-101
91
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.