The Human Arginase ELISA Kit is a reliable and accurate tool for detecting arginase levels in human samples such as serum, plasma, and cell culture supernatants. With high sensitivity and specificity, this kit ensures precise and reproducible results for a variety of research applications.Arginase is an enzyme that plays a key role in the urea cycle, converting arginine into urea and ornithine. Dysregulation of arginase has been implicated in various diseases such as cardiovascular disorders, metabolic syndromes, and immune-related conditions.
The measurement of arginase levels can provide valuable insights into the pathophysiology of these diseases and aid in the development of targeted therapies.Overall, the Human Arginase ELISA Kit offers researchers a valuable tool for studying arginase biology and its implications in health and disease. Its ease of use and reliability make it an essential component in any laboratory studying arginase-related pathways.
Product Name:
Human Arginase (Arg) ELISA Kit
Product Code:
HUDL00238
Size:
96 Assays
Target:
Arg
Synonyms:
ARG1, Arginase I, Liver Arginase
Detection Method:
Sandwich
Range:
3.125-200ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
90-101
95
EDTA plasma (n=5)
91-98
94
Heparin plasma (n=5)
90-99
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.