Human Alpha-L-iduronidase (IDUA) ELISA Kit (HUEB0452)
- SKU:
- HUEB0452
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P35475
- Range:
- 1.56-100 ug/mL
- ELISA Type:
- Sandwich
- Synonyms:
- IDUalpha, alpha-L-Iduronidase, IDUA, alpha ?L?Iduronidase, IDA, MPS1
- Reactivity:
- Human
Description
Human Alpha-L-iduronidase (IDUA) ELISA Kit
The Human Alpha-L-Iduronidase (IDUA) ELISA Kit is specifically designed for the accurate quantification of IDUA levels in human serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring precise and reproducible results for a variety of research applications.IDUA is a critical enzyme responsible for the breakdown of complex carbohydrates in the body. Deficiencies in IDUA can result in a rare genetic disorder known as mucopolysaccharidosis type I (MPS I), which can lead to severe developmental delays and organ dysfunction.
The measurement of IDUA levels is essential for monitoring disease progression and evaluating potential treatment options for MPS I patients.By utilizing the Human IDUA ELISA Kit, researchers can accurately assess IDUA levels in biological samples, providing valuable insights into disease mechanisms and guiding the development of novel therapeutic approaches for MPS I and other related disorders. Don't hesitate to trust in the reliability and accuracy of this advanced ELISA kit for your research needs.
Product Name: | Human Alpha-L-iduronidase (IDUA) ELISA Kit |
SKU: | HUEB0452 |
Size: | 96T |
Target: | Human Alpha-L-iduronidase (IDUA) |
Synonyms: | Alpha-L-iduronidase, IDUA, 3.2.1.76 |
Assay Type: | Sandwich |
Detection Method: | ELISA |
Reactivity: | Human |
Detection Range: | 1.56-100ng/mL |
Sensitivity: | 0.56ng/mL |
Intra CV: | 6.5% | ||||||||||||||||||||
Inter CV: | 11.7% | ||||||||||||||||||||
Linearity: |
| ||||||||||||||||||||
Recovery: |
|
Uniprot: | P35475 |
Sample Type: | Serum, plasma, tissue homogenates, cell culture supernates and other biological fluids |
Specificity: | Natural and recombinant human Alpha-L-iduronidase |
Sub Unit: | Monomer. |
Subcellular Location: | Lysosome |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | IDUA: Defects in IDUA are the cause of mucopolysaccharidosis type 1H (MPS1H); also known as Hurler syndrome. MPS1H is a severe form of mucopolysaccharidosis type 1, a rare lysosomal storage disease characterized by progressive physical deterioration with urinary excretion of dermatan sulfate and heparan sulfate. Patients with MPS1H usually present, within the first year of life, a combination of hepatosplenomegaly, skeletal deformities, corneal clouding and severe mental retardation. Obstructive airways disease, respiratory infection and cardiac complications usually result in death before 10 years of age. Defects in IDUA are the cause of mucopolysaccharidosis type 1H/S (MPS1H/S); also known as Hurler-Scheie syndrome. MPS1H/S is a form of mucopolysaccharidosis type 1, a rare lysosomal storage disease characterized by progressive physical deterioration with urinary excretion of dermatan sulfate and heparan sulfate. MPS1H/S represents an intermediate phenotype of the MPS1 clinical spectrum. It is characterized by relatively little neurological involvement, but most of the somatic symptoms described for severe MPS1 develop in the early to mid-teens, causing considerable loss of mobility. Defects in IDUA are the cause of mucopolysaccharidosis type 1S (MPS1S); also known as Scheie syndrome. MPS1S is a mild form of mucopolysaccharidosis type 1, a rare lysosomal storage disease characterized by progressive physical deterioration with urinary excretion of dermatan sulfate and heparan sulfate. Patients with MPS1S may have little or no neurological involvement, normal stature and life span, but present development of joints stiffness, mild hepatosplenomegaly, aortic valve disease and corneal clouding. Belongs to the glycosyl hydrolase 39 family. |
UniProt Protein Details: | Protein type:EC 3.2.1.76; Hydrolase; Glycan Metabolism - glycosaminoglycan degradation Chromosomal Location of Human Ortholog: 4p16.3 Cellular Component: lysosomal lumen Molecular Function:L-iduronidase activity; receptor binding Biological Process: carbohydrate metabolic process; cell morphogenesis; chemical homeostasis; chondroitin sulfate catabolic process; chondroitin sulfate metabolic process; dermatan sulfate catabolic process; disaccharide metabolic process; glycosaminoglycan catabolic process; glycosaminoglycan metabolic process; limb morphogenesis; lysosome organization and biogenesis; skeletal morphogenesis Disease: Hurler Syndrome; Hurler-scheie Syndrome; Scheie Syndrome |
NCBI Summary: | This gene encodes an enzyme that hydrolyzes the terminal alpha-L-iduronic acid residues of two glycosaminoglycans, dermatan sulfate and heparan sulfate. This hydrolysis is required for the lysosomal degradation of these glycosaminoglycans. Mutations in this gene that result in enzymatic deficiency lead to the autosomal recessive disease mucopolysaccharidosis type I (MPS I). [provided by RefSeq, Jul 2008] |
UniProt Code: | P35475 |
NCBI GenInfo Identifier: | 110611239 |
NCBI Gene ID: | 3425 |
NCBI Accession: | NP_000194.2 |
UniProt Secondary Accession: | P35475,B3KWK6, |
UniProt Related Accession: | P35475 |
Molecular Weight: | 71.9 kDa |
NCBI Full Name: | alpha-L-iduronidase |
NCBI Synonym Full Names: | iduronidase, alpha-L- |
NCBI Official Symbol: | IDUA |
NCBI Official Synonym Symbols: | IDA; MPS1 |
NCBI Protein Information: | alpha-L-iduronidase |
UniProt Protein Name: | Alpha-L-iduronidase |
Protein Family: | Alpha-L-iduronidase |
UniProt Gene Name: | IDUA |
UniProt Entry Name: | IDUA_HUMAN |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |