The General Lipoxin A4 (LXA4) ELISA Kit is a highly sensitive and specific assay designed for the accurate detection of Lipoxin A4 levels in various samples such as serum, plasma, and cell culture supernatants. This kit offers reliable and reproducible results, making it suitable for a wide range of research applications.Lipoxin A4 is a specialized pro-resolving mediator with anti-inflammatory and pro-resolving properties, playing a crucial role in the regulation of inflammation and immune responses.
Dysregulation of Lipoxin A4 levels has been linked to various inflammatory diseases, making it a valuable biomarker for studying these conditions and developing potential therapeutic interventions.Overall, the General Lipoxin A4 (LXA4) ELISA Kit provides researchers with a powerful tool for investigating the role of Lipoxin A4 in inflammatory processes and exploring its potential as a therapeutic target for inflammatory diseases.
Product Name:
General Lipoxin A4 (LXA4) ELISA Kit
Product Code:
UNDL00052
Size:
96 Assays
Target:
LXA4
Detection Method:
Competition
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. Note:To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 50µL standard or sample to each well.    And then add 50µL prepared Detection Reagent A immediately.    Shake and mix. Incubate 1 hour at 37°C
3.
Aspirate and wash 3 times
4.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
5.
Aspirate and wash 5 times
6.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
7.