Anti-Mouse CD317 [927] In Vivo Antibody - Ultra Low Endotoxin
Introducing the Anti-Mouse CD317 (927) In Vivo Antibody - Ultra Low Endotoxin from Assay Genie, a highly specific monoclonal antibody meticulously designed for in vivo applications.
This antibody targets the CD317 protein, which plays a vital role in immune response regulation, making it an essential tool for research in immunology and related fields. Featuring a [specified isotype if available], it ensures ultra low endotoxin levels (<0.1 EU/mg), making it highly suitable for applications such as ELISA, flow cytometry, and immunohistochemistry. Formulated in phosphate-buffered saline for optimal stability and performance, this antibody is available in various sizes to meet diverse research needs. Elevate your research accuracy and reliability with this superior antibody from Assay Genie. CD317, also known as BST2 or tetherin, is a protein involved in the innate immune response, particularly in the restriction of viral replication and release. It is expressed on a variety of cells, including immune cells, and plays a crucial role in antiviral defense mechanisms. Enhance your investigative studies into immune response and viral pathogenesis with the Anti-Mouse CD317 (927) In Vivo Antibody - Ultra Low Endotoxin.
Product Name:
Anti-Mouse CD317 (Clone 927) In Vivo Antibody - Ultra Low Endotoxin
Product Code:
IVMB0273
Size:
1 mg, 5 mg, 25 mg, 50 mg, 100 mg
Clone:
927
Protein:
CD317
Product Type:
Monoclonal Antibody
Synonyms:
BST2, tetherin, HM1.2 antigen, bone marrow stromal antigen 2, PDCA-1
Isotype:
IgG2b k
Reactivity:
Mouse
Applications:
Depletion, FA, FC, ICC, IF Microscopy, In Vivo
Formulation:
This monoclonal antibody is aseptically packaged and formulated in 0.01 M phosphate buffered saline (150 mM NaCl) PBS pH 7.2 - 7.4 with no carrier protein, potassium, calcium or preservatives added. Due to inherent biochemical properties of antibodies, certain products may be prone to precipitation over time. Precipitation may be removed by aseptic centrifugation and/or filtration.
Endotoxin Level:
<0.5 EU/mg as determined by the LAL method
Purity:
≥98% monomer by analytical SEC â‹… >95% by SDS Page
Product Preparation:
Functional grade preclinical antibodies are manufactured in an animal free facility using in vitro cell culture techniques and are purified by a multi-step process including the use of protein A or G to assure extremely low levels of endotoxins, leachable protein A or aggregates.
Applications:
Depletion, FA, FC, ICC, IF Microscopy, In Vivo
Reactivity:
Mouse
Host Species:
Rat
Specificity:
Clone 927 activity is directed against murine CD317 (BST2; PDCA-1).
Antigen Distribution:
Murine CD317 is expressed by IFN-producing cells in naïve mouse spleen and by a wide variety of cell lines including T cells, mast cells, B cells, fibroblast cells, and pluripotent embryonal carcinoma cells. Additionally, mice challenged by influenza or other stimuli (CpG, LPS, murine CMV, poly(I:C), and imiquimod) express CD317 in DC and other myeloid cells as well as T cells, B cells, NKT cells, and some NK cells. CD317 is also expressed on CD138+ plasma cells in naïve mice and is upregulated by viral stimulation.
Immunogen:
Mouse plasmacytoid dendritic cells
Concentration:
≥ 5.0 mg/ml
Endotoxin Level:
<0.5 EU/mg as determined by the LAL method
Formulation:
This monoclonal antibody is aseptically packaged and formulated in 0.01 M phosphate buffered saline (150 mM NaCl) PBS pH 7.2 - 7.4 with no carrier protein, potassium, calcium or preservatives added. Due to inherent biochemical properties of antibodies, certain products may be prone to precipitation over time. Precipitation may be removed by aseptic centrifugation and/or filtration.
Purity:
≥98% monomer by analytical SEC â‹… >95% by SDS Page
Preparation:
Functional grade preclinical antibodies are manufactured in an animal free facility using in vitro cell culture techniques and are purified by a multi-step process including the use of protein A or G to assure extremely low levels of endotoxins, leachable protein A or aggregates.
Storage and Handling:
Functional grade preclinical antibodies may be stored sterile as received at 2-8°C for up to one month. For longer term storage, aseptically aliquot in working volumes without diluting and store at -70°C. Avoid Repeated Freeze Thaw Cycles.
Monoclonal antibody (mAb) 927 recognizes CD317 (BST2; PDCA-1)1. CD317 is a specific marker of IFN-producing cells (IPCs aka plasmacytoid dendritic cells, DC) under naïve conditions. IPCs are early responders to viral infection and direct both the innate and adaptive immune response2,3. CD317 also promotes secretion in IPCs, presumably by sorting proteins between the Golgi apparatus and plasma membrane1. CD317 is located on the cell surface as well as intracellularly in the Golgi apparatus and is associated with lipid rafts.
CD317 is primarily present on the cell surfaces of murine IPCs in naïve mice, where its expression on resting and activated IPCs is independent of IFNs1. However, when stimulated with type I IFNs and IFN-gamma, cell surface expression of CD317 is induced on most cell types. When administered in vivo, treatment with mAb 927 abrogates IFN-α secretion by IPCs in response to CpG as well as depletes IPCs ~ 95%, significantly reducing plasma cells.
The 927 clone was generated to overcome barriers to the identification and study of IPCs caused by their scarcity in blood and tissues as well as their complex surface phenotype1. mAb 927 was generated by immunizing Wistar/CRL rats with bone marrow-derived IPCs with either CpG oligodeoxynucleotide 1826 or heat-killed Mycobacteria tuberculosis as adjuvant. Hybridoma lines were created by fusing popliteal lymph nodes with SP2/0 myeloma cells. Supernatants were screened for lines that recognize CD11c+B220+Ly-6c+CD11b-splenocytes. mAb 927 is rat IgG2b isotype.
Protein:
CD317
Function:
Recently identified antiviral protein that blocks the release of nascent retrovirus or other particles from infected cells.
Research Area:
Immunology
Pathogen Testing:
To protect mouse colonies from infection by pathogens and to assure that experimental preclinical data is not affected by such pathogens, all of Assay Genie's Purified Functional Antibodies are tested and guaranteed to be negative for all pathogens in the IDEXX IMPACT I Mouse Profile.